During the input sequence, if you make a mistake, you can press “C” to clear the previous input and start 
over again. 

 

Use only your fingers to key the combination. Sharp objects will result in damage, which is not covered by 
the warranty. 

 

If at any time during opening the lock or changing the combination, no keys are pressed for 10 seconds, 
the lock will return to a resting condition. If this occurs during a combination change, the old combination 

is retained. 

 

When opening or changing the combination on your lock, the ESL20XL will register the first 5 digits of the 
combination into the buffer that receives input. The 6th digit will be the last numeric key pressed. For 

example,  if  you  press 

C-1-2-3-4-5

-7-4-5-2-7

-6-#

  the  program  recognizes  only  the  C-1-2-3-4-5-6-# 

input. The last numeric key pressed continues to replace the one prior until the “#” key is pressed to 

indicate completion. This is a security feature that allows you to baffle any onlookers who may be trying 

to memorize your combination. 

 

Replacing the Batteries 

Always use a fresh set of name-brand Alkaline Batteries for best results. 

1.

 

Grip the keypad and rotate approximately 1/8 turn counter-clockwise to disengage the keypad from the 

base. 

2.

 

Carefully pull the keypad away from the base, taking care to not stress the cable that connects the keypad 
to the lock inside the safe.  
Do not allow the keypad to hang on the cable. 

3.

 

Lift the two 9-volt batteries out of the pockets where they are retained. 

4.

 

Carefully remove the battery clips from the end of the batteries, making sure you don’t pull on the wires 

and disconnect the battery clip from the PC board. 

5.

 

Snap on two new 9-volt batteries onto the clips, making sure they are tight with no loose contacts. 

6.

 

Press the two batteries back into their pockets, taking care to route the wires in the open cavity so they 

are not positioned where they will get pinched under the batteries when the keypad is placed on the base. 

7.

 

Replace the keypad on the base, starting with the top of the keypad around the 11:00 position, pressing 

down to seat it where the three retaining tabs go into the receiving slots, then rotate clockwise to vertical. 

You should feel a bit of a snap as it locks into position when the keypad is level. 

 
Advanced Access Control Features 

The ESL20XL is a Digital Safe Lock with many advanced features that address commercial and retail safe access control. 

These features include the following. Note that reference to Function Codes are abbreviated to F(2-digit code). See the 

Function Code Table for reference. 
 

 

Time Delay

 – Time delay forces the User to wait a pre-determined time period before the safe can be opened. This 

feature is a robbery deterrent, whereby the User can cooperate with a robber in opening the safe, but forces the robber 
to wait before access is granted. The idea is that a robber is too impatient to wait very long and gives up. Time delay 

periods are typically set for 10 or 15 minutes.  

o

 

This feature must be Enabled (F01). 

o

 

The ESL20XL can be set for a Delay Period from 1 to 99 minutes. (F02) 

o

 

If a User keys in a valid combination, the Time Delay is started.  

o

 

A flash of the LED lamp approximately 2 times per second indicates the Delay Period.  

o

 

At the end of the Delay Period, a long warbling tone is sounded to indicate the completion of the delay.  

Summary of Contents for ESL20XL

Page 1: ...hort good combination tone 7 Re key in the new 6 digit combination again 8 Press the key If the combination input matches the first pass you should hear a long good combination tone indicating your new combination has been recorded 9 Test your new combination several times prior to closing and locking the safe Note See the ESL20XL Beep and LED Patterns table on Page 10 See Changing User Combinatio...

Page 2: ...s from the end of the batteries making sure you don t pull on the wires and disconnect the battery clip from the PC board 5 Snap on two new 9 volt batteries onto the clips making sure they are tight with no loose contacts 6 Press the two batteries back into their pockets taking care to route the wires in the open cavity so they are not positioned where they will get pinched under the batteries whe...

Page 3: ...e Enabled F10 o The Master User or Manager is the only User with Administration capabilities o In Multi User mode there is no need for all Users to share the same combination as is the case with a mechanical combination lock o This feature allows the supervisor the ability to control the subordinate Users individually and makes employee turnover easier to manage because individual Users can be add...

Page 4: ...osure is the same as if someone had pushed a panic button to summon help By signaling secretly at the safe the User doesn t risk angering the robber and risking possible personal injury External Control This feature allows the ESL20XL to be disabled and enabled by an auxiliary device like an Access Manager a Key Switch external Alarm System or any other external switching method o This feature mus...

Page 5: ...The ESL20XL s advanced features are controlled only by the Master User and are set using Function Codes A function can be turned on and off or set using the Function Code with the Master User code as authorization for changing or setting the function A Function Code is a 2 digit code that is associated to a particular setting Each Function Code has a default or standard setting which is in the loc...

Page 6: ... 01 02 03 o To Enable Time Delay C 01 Master Code 1 o To Disable Time Delay C 01 Master Code 0 o To set the Delay Period C 02 Master Code Delay Period 1 99 minutes o To set the Open Period C 03 Master Code Open Period 1 9 minutes Multiple User Settings Functions 10 11 12 13 o To Enable Multiple User Mode C 10 Master Code 1 o To Disable Multiple User Mode C 10 Master Code 0 o To Add or Enable a Sub...

Page 7: ...Enable Armored Car TDL Bypass C 40 Master Code 1 Note Enabling Armored Car Bypass turns on enables User 9 which is the Armored Car User The User 9 combo must be set before this feature will function See Section 4 for changing instructions o To Disable Armored Car TDL Bypass C 40 Master Code 0 o To Enable Subordinate Authorizing User Armored Car TDL Bypass C 41 Master Code 1 o To Disable Subordinat...

Page 8: ...larm output will be caused any time the Duress code is entered by any User during opening or starting of Time Delay Requires Expansion Module o Enabling Dual Combo Mode automatically adds a User 1 even if Multi User Mode is disabled Don t forget to set a Code for User 1 or there will not be two codes to open the lock Record Keeping To track Function Settings use this table Date F Function Descript...

Page 9: ... lock inside the door The ESL20XL relies on a solenoid to actuate this bolt That solenoid can only overcome so much resistance and if that resistance is too great the bolt does not retract To resolve this problem you must find a handle position that does not push the locking system up against the lock s bolt To find that place it helps to know which way the handle turns when you open the door If y...

Page 10: ...lert after Time Delay 6 Beeps The lock is in Penalty Lockout During this period the lock will not accept any input You must wait for the penalty lockout to expire The lock will Beep Flash once when this period ends Short Warble 3 high low tones for about 2 5 seconds Short Good Combination Tone indicates the input is accepted during a Combination Change Long Warble 13 high low tones for about 10 se...