Adjusting Beeper Volume 

1.

 

Press the Menu key twice. 

2.

 

Press the More softkey 3 times. 

3.

 

Use the 

­

 and 

¯

 softkeys until the beeper volume bar graph is blinking. 

4.

 

Use 

¬

 and 

®

 

softkeys to adjust volume. 

5.

 

Press the “OK” key. 

 

 

Changing Language 

1.

 

Press the Menu key twice. 

2.

 

Press the More softkey 3 times. 

3.

 

Use the 

­

 and 

¯

 softkeys until the language is blinking. 

4.

 

Use 

¬

 and 

®

 

softkeys to adjust language. 

5.

 

Press the “OK” key. 

 

 

Immediate Lock 

Engaging Immediate Lock 

This  feature  is  used  when  Time  Lock  is  enabled  and  the  safe  is  in  an  open  period.  If 

Immediate Lock is selected, the safe is placed in a one-Time Lockout until the next open 

period.   

 

1.

 

Login. 

2.

 

Press the “1” (I-Lock) key from the Main Menu. 

3.

 

Select Open1 or Open2 using the softkeys below the left-hand side of the display. 

4.

 

Enter the number of hours that you want the system to remain locked out, up to 144 

hours. 

5.

 

Press ENTER. The system will display the time and date when the lockout period will 

end. Write that down so you remember it. 

 

Enabling Immediate Lock 

(this is an administrative)

 

1.

 

Login. 

2.

 

Press “3” (Admin). 

3.

 

Press “3” (Access). 

4.

 

Press “1” (Door Access). 

5.

 

Press “3” (Im Lock). 

6.

 

Enable or disable the feature for Lock 1 with the “YES/NO” key. 

7.

 

Press the “OK” softkey to save the change. 

8.

 

If applicable, repeat steps 6 and 7 for the second lock. 

 

Download an Audit 

1.

 

Login. 

2.

 

Press the “2” (Audit) key from the Main Menu. 

Summary of Contents for ESLAudit

Page 1: ...American Security Products ESLAudit Operating Instructions ESLAudit Access Control System Operating Instructions ...

Page 2: ...ings from a Backup File 6 Change PIN 6 User Administration 7 Adding Users restricted to managing user levels 7 Editing a User s Profile restricted to managing user levels 7 Deleting a User restricted to managing user levels 7 Enabling Disabling a User restricted to managing user levels 8 Purging All Users restricted to higher managing user levels 8 Dual Control restricted to Administrative user le...

Page 3: ...11 Duress 11 Aux Input 11 Holidays 12 Lock Setup 12 Lock Type 12 Door Hold Time 12 Door Open Time 12 Dual Control 12 Immediate Lock 12 Time Delay 12 Delay Period 12 Open Period 12 Time Lock 13 User Setup 13 Edit Users 13 Types of Users 13 View an Audit 14 ...

Page 4: ... car courier bypass for Time Delay and Time Lock Holiday lockout schedule with up to 16 programmable events per year Automatic daylight savings adjustment selectable and configurable Dual Control mode on any individual door Audit utility which allows PC based audit storage management data filter and sorting High contrast 4 lines by 21 characters backlit graphics display Optional burglary or duress...

Page 5: ... door within 4 seconds Batteries Changing the Batteries The battery compartment is locked on the bottom of the controller and holds two 9 volt batteries Pinch the release catches toward the center on either side to release the tray Battery Life The percentage of remaining battery life is displayed on the LOCKED screen To reach the LOCKED screen press any key when the lock is sleeping If the contro...

Page 6: ...aced in a one Time Lockout until the next open period 1 Login 2 Press the 1 I Lock key from the Main Menu 3 Select Open1 or Open2 using the softkeys below the left hand side of the display 4 Enter the number of hours that you want the system to remain locked out up to 144 hours 5 Press ENTER The system will display the time and date when the lockout period will end Write that down so you remember ...

Page 7: ...e a unique Flashdrive to avoid over writing data from other systems 1 Login 2 Press 4 USB 3 Press 1 Save System 4 Insert USB flash drive 5 Press the OK softkey Restoring Controller Settings from a Backup File Caution Restoring the system configuration from the USB Flashdrive will over write all current system settings If you have made any changes to the configuration or users at the Controller wit...

Page 8: ...login PINs that are in use by another user or that are deemed too simple will not be allowed Users can also be enrolled with the use of a PC application called ESLConfig Editing a User s Profile restricted to managing user levels 1 Login 2 Press 3 Admin 3 Press 2 Users 4 Press 2 Edit 5 Use and softkeys to scroll to find the user you wish to edit 6 Press the ENTER SAVE Key to select the user 7 Sele...

Page 9: ...estricted to Administrative user levels This feature requires two users working together to open a specified door 1 Login 2 Press 3 Admin 3 Press 3 Access 4 Press 1 Door Access 5 Press 2 DualCnt 6 Enable or disable the feature for Lock 1 with the YES NO key 7 Press the OK softkey to save the change 8 If applicable repeat steps 6 and 7 for the second lock Time Date Controls Setting Time Delay restr...

Page 10: ...s 2 Tm Lock 6 Enable or disable the feature for Lock 1 with the YES NO key 7 Press the OK softkey to save the change 8 If applicable repeat steps 6 and 7 for the second lock Daylight Savings Time restricted to administrative user levels 1 Login 2 Press 3 Admin 3 Press 3 Access 4 Press 2 Daylight Savings 5 Enable or disable this feature with the YES NO key 6 Press the OK key 7 Set the beginning tim...

Page 11: ...eboot 8 Remove the USB Flashdrive when complete Note User settings and system configuration are not changed with this process ESLConfig ESLConfig is a PC application that allows users to modify the settings of an ESLAudit system To use this utility you must first download the system settings from the applicable controller see page 6 After the ESLConfig program is installed on a PC and the program ...

Page 12: ...riately on the Sunday morning of the indicated week Duress Duress Alarm Enable will activate duress codes Duress codes are both one number higher and one number lower than any PIN value For example if your PIN is 515151 if you log into the system with either PIN 515152 or 515150 a duress signal will be sent to the monitoring station through the store s alarm system For this feature to function the...

Page 13: ... before the alarm goes off Dual Control This requires two users to open the specified door Immediate Lock If Immediate Lock is enabled and Time Lock is enabled when a user with the appropriate permissions presses I lock 1 from the Main Menu and selects a door the selected door is put into a one Time Lockout until the end of the I Lock period Time Delay To enable this feature check the Time Delay b...

Page 14: ... each day of the week By clicking on any of the three duplicate display setting boxes you can copy the settings for the day that is displayed to other days User Setup The second tab in the ESLConfig program is the User Setup tab Edit Users To edit users scroll through the user numbers with the Prev and Next buttons located on the upper right of the User Setup screen The Add and Del buttons are use...

Page 15: ...he Audit Trail Access modes are used to define key only PIN only and key PIN users You can save the file for later use with ESLConfig by clicking the File tab and then selecting Save You cannot safe a file to be uploaded to a controller with this method On the File tab select Output to Flashdrive and then All to save a file that can be uploaded into a controller The name of this file will be ESLAU...