background image

GUARDIAN CP

® 

DIGITAL CONTROL

FOR WELL PUMP & BOOSTER SYSTEMS

INSTALLATION & OPERATION INSTRUCTIONS

READ CAREFULLY THE 

PRODUCT INSTALLATION & 

OPERATION INSTRUCTIONS.  FAILURE TO FOLLOW THE 

INSTRUCTIONS AND WARNINGS IN THE MANUAL MAY 

RESULT IN SERIOUS OR FATAL INJURY AND/OR 

PROPERTY DAMAGE, AND WILL VOID THE PRODUCT 

WARRANTY.  THIS PRODUCT MUST BE INSTALLED BY A 

LICENSED PROFESSIONAL. FOLLOW ALL APPLICABLE 

LOCAL AND STATE CODES AND REGULATIONS. IN THE 

ABSENCE OF SUCH CODES, FOLLOW THE CURRENT 

EDITIONS OF THE NATIONAL PLUMBING CODE AND 

NATIONAL ELECTRIC CODE, AS APPLICABLE.

This product is used in conjunction 

with a system containing a tank 

under pressure, which may over time corrode, weaken and 

burst or explode, causing serious or fatal personal injury, 

leaking or flooding and/or property damage. To minimize risk, 

a licensed professional must install and periodically inspect 

and service the product and system. A drip pan connected to 

an adequate drain must be installed if leaking or flooding could 

cause property damage. Do not locate system in an area 

where leaking could cause property damage.

This control is capable of running 

pumps to pressures that may 

exceed the limitations of system components.  Never set the 

operating pressure higher than that of the safe system capacity.

This control can be adjusted to a narrow 

pressure differential. An improperly 

sized tank can cause the pump to cycle and lead to pump damage. 

This may require a larger pressure tank than is normally used.

ELECTROCUTION HAZARD

.  Must 

be installed by a licensed professional. 

First disconnect all electrical power before attempting service. 

For your safety, the installation and operation instructions must 

be followed to minimize the risk of electric shock, property 

damage or personal injury.

A water test must be taken before 

installation of any water treatment 

equipment. The water quality can significantly influence the life 

of your system. You should test for corrosive elements, acidity, 

total solids and other relevant contaminants, including chlorine 

and treat your water appropriately to insure satisfactory 

performance and prevent premature failure.

Use only lead-free solder and flux for 

all sweat-solder connections, as 

required by state and federal codes.

EXPLOSION OR RUPTURE 

HAZARD!

  A relief valve must be 

installed to prevent pressure in excess of local code requirement 

or maximum working pressure designated in the product 

manual, whichever is less.  Do not expose system to freezing 

temperatures or temperatures in excess of 130°. Failure to 

properly size the system or follow instructions in the manual 

may result in excessive strain on the system and may lead to 

product failure, leakage, flooding and/or property damage.

This product can expose you to 

chemicals including lead, which is 

known to the State of California to cause cancer and birth 

defects or other reproductive harm. For more information go to 

www.P65Warnings.ca.gov. 

Your Guardian CP DIGITAL CONTROL has been carefully assembled and factory tested. To enjoy the full service this 

unit can provide, you should read and follow all of the instructions in this manual. When all installation steps have been 

completed, make sure you also follow the startup, adjustment and operation instructions before using your AMTROL 

product. You should also read carefully the section describing proper product maintenance and follow the required 

procedures as you use your Guardian CP DIGITAL CONTROL. Keep this manual with the product. This manual may 

become out-of-date by later amendments. Check our web site, www.amtrol.com or ask your AMTROL supplier for any 

updates relating to your product. 

NOTE:

 Inspect for shipping damage. Notify freight carrier or store where purchased immediately if damage is present.  To 

avoid risk of personal injury and property damage, if the product appears to be malfunctioning or shows signs of corrosion, 

call a licensed professional immediately.  Current copies of the product manual can be viewed at www.amtrol.com.  Use 

proper safety equipment when installing.

THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL 

INJURY AND OTHER HAZARDS. OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS 

SYMBOL TO REDUCE THE RISK OF PERSONAL INJURY AS WELL AS PROPERTY DAMAGE.

Model DC2

INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.

Summary of Contents for GUARDIAN CP DC2

Page 1: ...ter appropriately to insure satisfactory performance and prevent premature failure Use only lead free solder and flux for all sweat solder connections as required by state and federal codes EXPLOSION OR RUPTURE HAZARD A relief valve must be installed to prevent pressure in excess of local code requirement or maximum working pressure designated in the product manual whichever is less Do not expose ...

Page 2: ...B FT of torque NOTE Do not allow pipe sealant or other contaminants to enter the small port in the Guardian CP connection NOTE A mechanical pressure gauge is not required Use the appropriate plug to block any unused ports Electrical Connection ELECTROCUTION HAZARD FIRST DISCONNECT ALL ELECTRICAL POWER BEFORE SERVICING ELECTROCUTION HAZARD THE Guardian CP MUST BE ELECTRICALLY GROUNDED NOTE The Guar...

Page 3: ... shuts off NOTE Press a third time to display the last Error Code in memory see Error Code table If no errors have occurred the display will show 4 After approx 10 seconds Pr will appear indicating the settings are programmed Display will then revert to line pressure NOTE Settings will be stored until changed manually even if there is a power failure NOTE If pump cannot reach cut out setting withi...

Page 4: ...CP error encountered Faulty pump Improper wiring Guardian CP or pump Check circuit breaker and wiring connections See error chart below Contact pump manufacturer Check wiring per manufacturer s instructions Water flow stops before cut in Tank precharge too high Adjust precharge per manufacturer s instruction Display reads upside down Mounting position may vary Press 5 6 together for 3 seconds and ...

Page 5: ...ecuada para asegurar un rendimiento satisfactorio y evitar fallos prematuros ADVERTENCIA Utilice únicamente soldaduras sin plomo y fundentes para todas las conexiones por soldadura de estaño tal y como exigen los códigos estatales y federales ADVERTENCIA PELIGRO DE EXPLOSIÓN O RUPTURA Debe instalarse una válvula de alivio para evitar que la presión supere los requisitos del código local o la presi...

Page 6: ...ador de tuberías u otros contaminantes entren en el pequeño puerto de la conexión Guardian CP NOTA No es necesario un manómetro mecánico Utilice el tapón adecuado para bloquear los puertos no utilizados Conexión eléctrica PELIGRO PELIGRO DE ELECTROCUCIÓN DESCONECTE PRIMERO TODA LA ENERGÍA ELÉCTRICA ANTES DE REALIZAR EL MANTENIMIENTO PELIGRO PELIGRO DE ELECTROCUCIÓN El Guardian CP DEBE ESTAR CONECT...

Page 7: ...e una tercera vez para visualizar el último Código de Error en la memoria véase la tabla de Códigos de Error Si no se ha producido ningún error la pantalla mostrará 4 Después de unos 10 segundos aproximadamente aparecerá Pr lo que indica que los ajustes están programados La pantalla volverá a mostrar la presión de la línea NOTA Los ajustes se guardarán hasta que se cambien manualmente incluso si h...

Page 8: ...ba defectuosa Cableado incorrecto Guardian CP o bomba Compruebe el disyuntor y las conexiones del cableado Consulte el cuadro de errores que aparece a contin uación Póngase en contacto con el fabricante de la bomba Compruebe el cableado según las instrucciones del fabricante El flujo de agua se detiene antes del corte Precarga del tanque demasiado alta Ajuste la precarga según las instrucciones de...

Page 9: ...tes et éviter une défaillance prématurée AVERTISSEMENT N utilisez que de la soudure et du flux sans plomb pour toutes les connexions de soudure comme l exigent les codes nationaux et fédéraux AVERTISSEMENT RISQUE D EXPLOSION OU DE RUPTURE Une soupape de décharge doit être installée pour éviter que la pression ne dépasse les exigences du code local ou la pression de service maximale indiquée dans l...

Page 10: ... de produit d étanchéité pour tuyau ou d autres contaminants pénétrer dans le petit orifice de la connexion du Guardian CP REMARQUE Un manomètre mécanique n est pas nécessaire Utilisez la prise appropriée pour bloquer tous les ports inutilisés Connexion électrique RISQUE D ÉLECTROCUTION DÉBRANCHEZ D ABORD TOUTE L ALIMENTATION ÉLECTRIQUE AVANT L ENTRETIEN RISQUE D ÉLECTROCUTION LE Guardian CP DOIT ...

Page 11: ...pe s éteint REMARQUE Appuyez sur une troisième fois pour afficher le dernier code d erreur en mémoire voir Tableau des codes d erreur Si aucune erreur ne s est produite l affichage indique 4 Après environ 10 secondes Pr s affiche indiquant que les paramètres sont programmés L affichage revient alors à la pression de ligne REMARQUE Les paramètres sont stockés jusqu à ce qu ils soient modifiés manue...

Page 12: ...ée Pompe défectueuse Câblage incorrect Guardian CP ou pompe Vérifiez le disjoncteur et les connexions du câblage Voir le tableau des erreurs ci dessous Contactez le fabricant de la pompe Vérifiez le câblage selon les instructions du fabricant Le débit d eau s arrête avant l activation Précharge du réservoir trop élevée Réglez la précharge selon les instructions du fabricant L affichage se lit à l ...

Reviews: