System Tested and Certifi ed against
NSF/ANSI Standard 42, 53, and 55.
Manufactured by Access Business Group LLC, Ada, MI 49355
Product Information Number:
In the United States, call 1-616-787-6279 weekdays between 9 a.m. and 5
p.m. Eastern time.
In Canada, call 1-519-685-7882 weekdays between 8 a.m. and 5 p.m. Eastern time.
In addition, NSF International has verifi ed the water treatment claims for this
model for the reduction of specifi c substances which are not included in NSF/
ANSI Standard 53 or Standard 42 as follows:
Additional Contaminants
Chemical
% Reduction
Influent Concentration
Effluent
(µg/L)
Concentration
(µg/l)
EPA Priority Pollutants
Acenaphthene >99.7
67.9
<DL
Acenaphthylene >99.7
44.9
<DL
Aldrin 97.4
14.4
0.38
Anthracene >99.6
0.0106
<DL
Benzidine >99.6
2.54
<DL
Benzo[a]anthracene >99.3
0.224
<DL
Benzo[a]pyrene 92.5
0.0605
0.00456
Benzo[b]fluoranthene 98.7
0.316
0.00416
Benzo[g,h,i]perylene 91.0
0.434
0.0390
Benzo[k]fluoranthene 98.1
0.325
0.00611
alpha-BHC >99.6
80.6
<DL
beta-BHC >99.6
81.4
<DL
delta-BHC >99.6
77.8
<DL
gamma-BHC >99.6
80.9
<DL
Bis(2-Chloroethoxy)methane >99.3
136
<DL
Bis(2-chloroethyl) ether
>99.0
213
<DL
Bis(2-chloroisopropyl) ether
>98.3
206
<DL
Bis(2-ethyl-hexyl) phthalate
99.0
199
2
4-Bromophenyl phenyl ether
>99.1
225
<DL
Butyl benzyl phthalate
>99.4
226
<DL
4-Chloro-3-methylphenol >99.1 171 <DL
2-Chloroethyl vinyl ether
>99.9
298
<DL
2-Chlorophenol >98.1
175
<DL
4-Chlorophenyl phenyl ether
>99.1
197
<DL
Chrysene >97.8
0.232
<DL
4,4’-DDD 97
59.4
1.7
Di-n-butyl phthalate
>99.6
245
<DL
Di-n-octyl phthalate
>98.8
179
<DL
Dibenzo[a,h]anthracene
93.4
0.524
0.0345
1,3-Dichlorobenzene >99.8
99.7
<DL
3,3’-Dichlorobenzidine >99.6 4.89
<DL
2,4-Dichlorophenol >98.7
161
<DL
trans-1,3-Dichloropropene >99.9 163 <DL
Dieldrin 99.7
132
0.43
Diethyl phthalate
>99.7
202
<DL
Dimethyl phthalate
>99.8
197
<DL
2,4-Dimethylphenol >98.7
167
<DL
4,6-Dinitro-2-methyl phenol
>99.3
57.4
<DL
2,4-Dinitrotoluene >94.3
175
<DL
2,6-Dinitrotoluene >95.1
204
<DL
1,2-Diphenylhydrazine >99.0
161
<DL
alpha-Endosulfan 97.1
75.6
2.20
beta-Endosulfan 97.5
79.4
1.95
Endosulfan Sulfate
95.4
85.2
3.95
Endrin Aldehyde
>99.0
20.3
<DL
Fluoranthene >98.2
0.303
<DL
Fluorene >99.7
7.56
<DL
Hexachlorobenzene >98.8
84.3
<DL
Hexachloroethane >96.6
46.6
<DL
Isophorone >98.4
177
<DL
Naphthalene >99.7
23.4
<DL
Nitrobenzene >98.5
156
<DL
2-Nitrophenol >99.5
150
<DL
4-Nitrophenol >99.8
57.6
<DL
N-Nitroso-di-n-propylamine >99.2 157 <DL
N-Nitrosodiphenylamine >99.1
147
<DL
PCB-1016 >98.8
57.9
<DL
PCB-1221 >99.6
49.7
<DL
Additional Contaminants
Chemical
% Reduction
Influent Concentration
Effluent
(µg/L)
Concentration
(µg/l)
EPA Priority Pollutants
PCB-1232 >98.4
30.9
<DL
PCB-1242 >99.2
35.5
<DL
PCB-1248 >99.4
35.6
<DL
PCB-1254 >97.5
40.3
<DL
Phenanthrene >99.0
0.0752
<DL
Phenol >98.1
68.7
<DL
Pyrene >98.1
0.328
<DL
Strychnine >99.8
47.5
<DL
TCDD 2,3,7,8-
Tetrachlorodibenzoparadioxin >99.9
0.0131
<DL
TCDF 2,3,7,8-
Tetrachlorodibenzofuran >99.9 0.0269
<DL
2,4,6-Trichlorophenol >98.7
168
<DL
1,2,3-Trichloropropane >99.4 86.8
<DL
Vinyl Chloride
>93.9
8.2
<0.5
Non-EPA Priority Pollutant
Aldicarb 99.8
103
0.21
Carbaryl >98.3
511
<DL
Chlorpyrifos >99.9
212
<DL
4,4’-Dibromo-1,1’-biphenyl 95.7 46.0 2.00
Guthion >99.9
46.1
<DL
Hydrocarbons >91.3
1150
<DL
Malathion >99.0
217
<DL
Parathion 99.9
212
<DL
Rated Flow Speed: 0.9 gallons per minute (3.4 L/min)
Capacity of Filter Cartridge: 1320 gallons (5000 L) or one year service
Maximum Working Pressure: 125 psi (862 kPa)
Minimum Pressure: 15psi (103.5 kPa)
Maximum Water Temperature: 75° F (24°C)
Minimum Water Temperature: 40º F (4.4º C)
Electrical Rating
Input: 120 V~, 1.8 A/50-60Hz
Output: 19V DC, 3.16A
General Installation Conditions and Needs: See Owner’s Manual
General Operation and Maintenance Requirements: See Owner’s Manual
Explanation of Performance Indicator: See Owner’s Manual
Manufacturer’s Limited Warranty: See Owner’s Manual
Installation must comply with local, regional, or national laws and regulations.
The contaminants listed above for reduction by the
eSpring
™
Water Purifi er are
not necessarily in your water.
The Water Purifi er has been certifi ed for the reduction of radon from drinking
water and not for other potential radon sources. The water purifi er should not be
used on drinking water containing radon levels in excess of 4000 pCi/L.
While testing of this system was performed under standard laboratory condi-
tions, your actual performance may vary.
CAUTION:
Do not use where water is microbiologically unsafe or with water of
unknown quality without adequate disinfection before or after the system.
20
Summary of Contents for eSpring
Page 67: ...21 ...