Replacing the Battery
58
6" Color Video Touch Panels
14.
Grip the CV6 unit, from either sides of the enclosure, and while angling the front of the CV6
unit upwards, connect the AXlink and/or BNC connectors.
15.
Carefully insert the CV6 unit into the enclosure.
16.
Position the faceplate/bezel (
D
in FIG. 17 on page 15) above the enclosure base.
17.
Insert the mounting blocks (
B
in FIG. 17 on page 15) into the opening below both sides of the
faceplate. The elevated groove on the blocks should lie against the base enclosure.
18.
Insert two of the provided enclosure screws into each of the mounting blocks and secure the
bracket to the faceplate by turning the screws using a clockwise motion. Repeat this step for
the second mounting bracket.
AXD-CV6 Battery Replacement
To remove the lithium battery from the touch panel:
1.
Discharge the static electricity from your body by touching a grounded object and remove the
magnetically attatched the faceplate.
2.
Removing the main unit:
From the CB-CV6 conduit/wallbox by carefully unscrewing the four-#4 screws from the
threaded inserts located along the sides of the housing. Refer to FIG. 5 on page 7 for
more information.
From solid/flat surface by carefully unscrewing the four-#4 screws from the threaded
inserts located along the sides of the housing. Refer to FIG. 6 on page 8 for more
information.
From a plasterboard (drywall) surface by carefully unscrewing the two screws from the
drywall clips. Once these drywall clips are separated from their screws, the drywall clip
set must be re-order from AMX before the unit can be mounted to this type of surface
again. Refer to FIG. 10 on page 11 for more information.
3.
Pull the touch panel forward until the whole unit slides out of the surface/wallbox.
4.
Disconnect all the connectors to remove the touch panel from the conduit/wallbox or
equipment rack.
5.
Place the touch panel facedown onto a soft cloth and begin unscrewing the four screws
securing the housing to the main unit. Refer to FIG. 6 on page 8 for more information.
6.
Remove the touch overlay’s ribbon cable connectors from the circuit card.
7.
Remove the upper circuit card and turn it over.
8.
Carefully pry the battery out of its socket and insert the new battery.
9.
Replace the circuit card and insert/tighten the circuit card spacers.
10.
Connect the touch overlay’s ribbon cable connector to the circuit card.
11.
Re-insert and tighten the housing screws to its four locations along the outside of the housing.
12.
Return the touch panel to the backbox or equipment rack and connect the AXlink connector.
13.
Insert the four mounting screws/two expansion clips, and tighten.
14.
Put the magnetic faceplate back onto the main unit and verify that it is secure.