For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).
12/09
©2009 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.
AMX reserves the right to alter specifications without notice at any time.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com
93-0552-52
REV: A
Note that the Hydraport Base Assembly travels up and down approximately 228.6 mm
(9”) during operation.
The service loop must accommodate this motion and provide for securing the cable to
the Hydraport Base Assembly for strain relief.
For more detailed information, please refer to the HPX-1600-XX Hydraport Base
Assembly Instruction Manual.
Step 3 - Insert the Module Into the HPX-1600 Chassis
Insert the module into the main chassis of the HPX-1600 Base Assembly.
Note the position of module interlock tab: this tab should face towards the bottom of
the HPX-1600 Base assembly when installed in its mounted position (FIG. 6).
Step 4 - Install the Bottom Cover On the HPX-1600
Note
: Install any remaining modules into the Hydraport Base Assembly before
installing the Bottom Cover on the HPX-1600.
1.
Install the bottom cover (including the Power Inlet Assembly) onto the bottom of
the main frame of the Hydraport Base Assembly.
The cables from the HPX-C5400-CN+A Module as well as all other modules
(except AC Power Outlets) will exit the bottom of the Hydraport Base Assembly
through one of four square passages on either side of the bottom cover.
2.
After the bottom cover is secured using four screws, secure the cables to the
corresponding tab near each opening using a small cable tie (FIG. 7).
FIG. 6
Inserting the Component AV Module into the HPX-1600 Chassis
HPX-1600
Base Assembly
(bottom)
Module Interlock Tab
Component AV Module
FIG. 7
Bottom Cover - Installed With Cables Exiting and Secured
HPX-1600 Chassis
Aluminum Frame (bottom)
Wire Tie
Wire Tie
Bottom Cover
(secured with 4
mounting screws)
Cable
Cable