Basic Operations
29
IREdit
7.
After several seconds, the panel should appear in the online device tree, listed as
Virtual
NetLinx Master
. Once you can see the device online, you may transfer panel files to the G4
device without the need for an intermediate NetLinx master.
Configuring IREdit for Virtual NetLinx Master Transfers
1.
Select
Tools > Comm Settings...
to open the Communications Settings dialog.
2.
Select the
Virtual NetLinx Master
radio button.
3.
Click the
Settings
button to access the Virtual NetLinx Master Settings dialog.
4.
Enter the system number and select
OK
.
Powering Up and Connecting the Panel
1.
Verify that an USB cable is connected to the panel.
2.
Connect the terminal end of the PSN6.5 power cable to the 12 VDC power connector on the
rear/side of the touch panel.
Transferring Files Using a Virtual NetLinx Master Connection
Once you have configured both the touch panel and IREdit for Virtual NetLinx Master Transfers,
you are ready to transfer files to the panel without the need for an intermediate master:
Sending Files To the Panel:
1.
With your IR file selected in the Navigator window, select
Tools > Send
, to open the Send IR
dialog.
2.
Enter the information for
Device, Port
and
System
.
3.
After you have all the necessary information listed, click Start. You will then see a status bar.
4.
Once it is done sending you can select Close. The status will read "Disconnecting".
In the Send IR dialog, under the Send section, be sure it reads Connected to device.
Panels cannot send IR data to IREdit via USB.