Landmark Cinema Quick Setup Guide
Introduction
3
The green LINK LED will blink in synch with the green DATA LED at the upper
right corner of the rear panel of the PMB-CF2. This indicates that there is
communication between the PLC-MCU card and the PMB-CF2 cardframe.
The red DIAG LED indicates whether the Cinema project's program is running
from the PLC-MCU's own onboard memory or from an attached PC. If the PLC-
MCU is operating from the program in its own memory, the red DIAG LED will
blink briefly for 1/10 second in each second, something like a heartbeat pattern. If
the PLC-MCU is connected to a PC and the program is running from the PC instead
of the PLC-MCU, the red DIAG LED will blink on and off in equal 1/2-second
intervals.
The green LED on the PLC-IROUT card will only blink when sending an IR signal
out from the card.
PMB-TCC Television Control Center
The PMB-TCC has four IR outputs on the rear panel, as shown in Figure 2. Each IR
output connects to an IR emitter that must be compatible with whatever device(s)
it controls. Connection to the PMB-CF2 is via a PhastLink cable that plugs into a
PhastLink RJ-45 port on the rear of the unit.
The green LINK LED on the front of the PMB-TCC (Figure 3) will blink in synch
with the green DATA LED at the upper right corner of the rear panel of the PMB-
CF2. This indicates that there is communication between the PMB-TCC and the
PMB-CF2 cardframe. The IR-OUT LED on the front of the PMB-TCC will blink
whenever IR code is sent to an IR emitter from the PMB-TCC.
Figure 2
PMB-TCC Television Control
Center (rear view)