Wiring and Connections
12
Metreau Entry Communicators
Ferrite Installation (Required)
Metreau Entry Communicators comes with a Cat5 Suppression Ferrite that must be clipped around the
Ethernet cable, inside the wall box (no tools required).
When positioning the Ferrite clip inside the wall box, place the bottom of the clip flat against the back
inside surface of the wall box, to allow sufficient room for the Metreau Entry Communicator unit
(FIG. 9).
FIG. 8
Installing the CAT5 Suppression Ferrite
FIG. 9
Fitting the Ferrite clip and Ethernet cable inside the Conduit Box
1. Release the latch to open
the plastic enclosure.
2. Insert the Cat5 cable
and close the enclosure.
3. Installation complete.
Wall Box (front view)
Ethernet cable and connector
Ferrite clip installed on
Ethernet cable
Ensure that the Ferrite clip is resting flat
against the inside back surface of the
wall box to allow room for the
Metreau Entry Communicator unit