Mounting and Installation
24
Metreau Entry Communicators
6.
Place the lug of the ground wire on the device and the Earth ground wire around the provided screw
and connect them both to the point shown in FIG. 17.
7.
Install the (provided) Ferrite clip onto the Ethernet cable (see FIG. 8 on page 12).
8.
Connect the Ethernet cable in the back of the Metreau Entry Communicator.
9.
Insert and fasten the Metreau Entry Communicator into the wall box.
Removing the Device From the Wall
The installation housing for the Metreau Entry Communicators are made to such exacting specifications
it will always be a snug fit. Should you ever need to remove the Metreau Entry Communicator from the
wall, follow these steps:
1.
Place a flathead screwdriver between the tab of the wall box and the notch of the Metreau Entry
Communicator and pop the two apart.
2.
Pull the bottom of the unit out (pivoting on the top clip) until it seems to bind against the shielding
3.
While keeping the unit at this angle, pull the top of the unit away from the top clip.
The device and wall box
must
have an Earth ground.
Start at the top of the device and tilt in toward the bottom.