Programming the Mio R-4
58
Mio Modero R-4
"^" Button Commands (Cont.)
^BWW
Set the button
word wrap
feature to those
buttons with a
defined address
range.
Set the button word wrap feature to those buttons with a defined address range. By
default, word-wrap is Off.
Syntax:
"'^BWW-<vt addr range>,<button states range>,<word wrap>'"
Variable:
• variable text address range = 1 - 4000.
• button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
• word wrap = (0=Off and 1=On). Default is Off.
Example:
SEND_COMMAND Device,"'^BWW-500,1,1'"
Sets the word wrap on for the button’s Off state.
^CPF
Clear all page flips
from a button
Clear all page flips from a button.
Syntax:
"'^CPF-<vt addr range>'"
Variables:
• variable text address range = 1 - 4000.
Example:
SEND_COMMAND Remote,"'^CPF-500'"
Clears all page flips from the button.
^DPF
Delete page flips
from button if it
already exists
Delete page flips from button if it already exists.
Syntax:
"'^DFP-<vt addr range>,<actions>,<page name>'"
Variable:
• variable text address range = 1 - 4000.
• actions =
Stan
[dardPage] - Flip to standard page
Prev
[iousPage] - Flip to previous page
Show
[Popup] - Show Popup page
Hide
[Popup] - Hide Popup page
Togg
[lePopup] - Toggle popup state
ClearG
[roup] - Clear popup page group from all pages
ClearP
[age] - Clear all popup pages from a page with the
specified page name
ClearA
[ll] - Clear all popup pages from all pages
• page name = 1 - 50 ASCII characters.
Example:
SEND COMMAND Device,"'^DPF-409,Prev'"
Deletes the assignment of a button from flipping to a previous page.
^ENA
Enable or
disable buttons
with a set
variable text
range
Enable or disable buttons with a set variable text range.
Syntax:
"'^ENA-<vt addr range>,<command value>'"
Variables:
• variable text address range = 1 - 4000.
• command value = (0= disable, 1= enable)
Example:
SEND_COMMAND Device,"'^ENA-500.504&510.515,0'"
Disables button pushes on buttons with variable text range 500-504 & 510-515.