Troubleshooting
202
7" Modero Touch Panels
Troubleshooting Information (Cont.)
Symptom
Solution
I updated my panel firmware but
my Battery Base page doesn’t
seem to be working properly.
• Cycle power manually to the panel and check the Battery Base page
after startup.
• Verify that you are using the most current v2.XX Modero firmware.
• If downloading the firmware to the panel via a COM port, try using an
IP Address and retry the download of the firmware to the panel.
My Modero panel isn’t appearing
in my Workspace window.
• Verify that the System number is the same on both the NetLinx
Workspace window and the System Settings page on the Modero
panel.
• Verify you have entered the proper NetLinx Master IP and connection
methods into the Master Connection section of the System Settings
page.
My Modero panel can’t obtain a
DHCP Address
In requesting a DHCP Address, the DHCP Server can take up to a few
minutes to provide the address.
• Verify there is an active Ethernet connection attached to the rear of
the Modero before beginning these procedures.
• Select
Diagnostics
>
Network Address
, from the Main menu and
verify the System number.
• If the IP Address field is still empty, give the Modero a few minutes to
negotiate a DHCP Address and try again.
My NXT-BP battery pack is
blinking when I check the battery
life indicator.
• A blinking battery life LED indicates that there is less than 10% power
charge remaining on the battery.
• It is recommended that you fully charge the battery either in the
NXA-BASE/1 battery base or in the NXT-CHG battery charger.
• Refer to the
NXA-BASE/1 Battery Base Kit (FG2255-05K)
section on
page 24 and
NXT-CHG Battery Charger Kit (FG2255-50K)
section
on page 28 for more information.
My panel is not showing up in the
Virtual Master’s System list of
connected devices.
If you a Virtual Master has already connected to the target panel, the
G4 device retains the information of the previous Virtual Master System
number.
• Reboot the panel without the USB cable plugged into the panel.
• Configure NetLinx Studio for a Virtual Master connection. Note the
System Number used in the Edit Settings window.
• Stop communication on the Virtual Master by going to
Settings
>
Stop Communications
.
• Click
Yes
to stop communication.
• Select the System Number (from the Online Tree tab) and use a right
mouse click to select
Refresh System
. This re-establishes
communication with the Virtual Master.
• Plug-in the mini-USB cable into the corresponding port on the panel.
• Wait a few seconds and refresh the system. This re-establishes
communication with the Virtual Master. The panel should now appear
in the list of available devices.
Summary of Contents for Modero CV7
Page 1: ...Operation Reference Guide Touch Panels NXD T CV7 7 Modero Touch Panel Last Revised 10 19 2011...
Page 42: ...CV7 Touch Panel Accessories 30 7 Modero Touch Panels...
Page 58: ...Installation 46 7 Modero Touch Panels...
Page 194: ...Programming 182 7 Modero Touch Panels...
Page 200: ...Appendix A 188 7 Modero Touch Panels...
Page 211: ...Appendix B Wireless Technology 199 7 Modero Touch Panels...
Page 212: ...Appendix B Wireless Technology 200 7 Modero Touch Panels...
Page 218: ...Troubleshooting 206 7 Modero Touch Panels...