Configuring Communication
50
7" Modero Touch Panels
7.
Press the on-screen
Reboot
button to restart the panel and incorporate any changes.
8.
Obtain the System Number and Master IP Address from NetLinx Studio. This information must be
specific for the system used with the configured Modero panel.
9.
Press the grey Front Setup Access button for
3 seconds
to open the Setup page.
10.
Press the
Protected Setup
button (located on the lower-left of the panel page) to open the Protected
Setup page.
11.
Press the
System Settings
button (located on the Protected Setup page) to open the System Settings
page (FIG. 51) and begin configuring the communication settings on the panel to match those of the
target Master.
FIG. 50
Protected Setup page
Before continuing, open NetLinx Studio. This program assists in developing a System
Number, Master IP/URL, and Master Port number. Refer to your NetLinx Master’s
instruction manuals for more information.
FIG. 51
System Settings page
MAC Address
NetLinx Master’s
connection
Modero
connection
information
from panel is
factory set to a
unique address
information
There are 2 possible Master Connection Types available:
USB
or
Ethernet
.
A USB connection type is a
direct connection
from the panel’s mini-USB port to a
corresponding USB port on the PC (acting as a Virtual Master).
An Ethernet connection type involves indirect communication from the panel to a
Master via an Ethernet connection to the network.
Summary of Contents for Modero CV7
Page 1: ...Operation Reference Guide Touch Panels NXD T CV7 7 Modero Touch Panel Last Revised 10 19 2011...
Page 42: ...CV7 Touch Panel Accessories 30 7 Modero Touch Panels...
Page 58: ...Installation 46 7 Modero Touch Panels...
Page 194: ...Programming 182 7 Modero Touch Panels...
Page 200: ...Appendix A 188 7 Modero Touch Panels...
Page 211: ...Appendix B Wireless Technology 199 7 Modero Touch Panels...
Page 212: ...Appendix B Wireless Technology 200 7 Modero Touch Panels...
Page 218: ...Troubleshooting 206 7 Modero Touch Panels...