Programming
73
Modero G4 Touch Panels - Configuration and Programming
"^" Button Commands (Cont.)
^BSP
Set the button size and its position on the page.
Syntax:
"'^BSP-<vt addr range>,<left>,<top>,<right>,<bottom>'"
Variables:
variable text address range = 1 - 4000.
left = position of left edge of the button on the panel
top = position of the top edge of the button on the panel
right = position of right edge of the button on the panel
bottom = position of the bottom edge of the button on the panel
Example:
SEND_COMMAND panel,"'^BSP-530,20,100,50,130'"
Makes the button with variable text address 530 appear at (20,100) and be 30px by 30px
^BVL
Log-On/Log-Off the computer control connection.
Syntax:
"'^BVL-<vt addr range>,<connection>'"
Variables:
variable text address range = 1 - 4000.
connection = 0 (Log-Off connection) and 1 (Log-On connection).
Example:
SEND_COMMAND Panel,"'^BVL-500,0'"
Logs-off the computer control connection of the button.
^BVN
Set the computer control remote host for the specified address.
Syntax:
"'^BVN-<vt addr range>,<remote host>'"
Variables:
variable text address range = 1 - 4000.
remote host = 1 - 50 ASCII characters.
Example:
SEND_COMMAND Panel,"'^BVN-500,191.191.191.191'"
Sets the remote host to '191.191.191.191' for the specific computer control button.
^BVP
Set the network password for the specified address.
Syntax:
"'^BVP-<vt addr range>,<network password>'"
Variables:
variable text address range = 1 - 4000.
network password = 1 - 50 ASCII characters.
Example:
SEND_COMMAND Panel,"'^BVP-500,PCLOCK'"
Sets the password to PCLOCK for the specific PC control button.
^BVT
Set the computer control network port for the specified address.
Syntax:
"'^BVT-<vt addr range>,<network port>'"
Variables:
variable text address range = 1 - 4000.
network port = 1 - 65535.
Example:
SEND_COMMAND Panel,"'^BVT-500,5000'"
Sets the network port to 5000.