background image

For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).

 5/10

©2010 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.

AMX reserves the right to alter specifications without notice at any time. 

3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com

   93-5967-01

 

REV: A

power or wireless connection fails during a firmware upgrade, the panel flash 
file system may become corrupted.

Setup Pages

The panel is equipped with setup pages that allow you to set and configure 
various features on the panel. Consult the 

MVP-9000i Operation/Reference 

Guide

 for detailed information on the 

Setup

 pages.

Accessing The Protected Setup Page

1.

Press down and hold both the bottom left pushbutton and down on the 
directional pad (indicated in FIG. 1) simultaneously for 3-5 seconds. This 
opens the 

Setup

 page.

2.

Press the 

Protected Setup

 button on the Setup page. This opens a 

 

keypad for password entry.

3.

Enter the panel password into the keypad (default is 

1988)

 and select 

Done

 to access the 

Protected Setup

 page.

Setting the Panel’s Device Number

In the 

Protected Setup

 page:

1.

Press the 

Device Number

 field to open the Device Number keypad.

2.

Enter a unique Device Number assignment for the panel

3.

Press 

Done

 to return to the 

Protected Setup

 page.

Configuring the Panel’s Wireless IP Settings

The first step is to configure the wireless communication parameters. This only 
configures the card to communicate to a target WAP and it is still necessary to 
tell the panel which Master it should be communicating with; see 

Master 

Connection

.

Consult the 

MVP-9000i Modero ViewPoint Touch Panels Operation/Reference 

Guide

 for setting the wireless communication using a static IP address.

Wireless Communication Using a DHCP Address

In the 

Protected

 

Setup

 page:

1.

Select 

Wireless Settings

. Wireless communication is set within the IP 

Settings section of this page. 

2.

Toggle the 

DHCP/Static

 field (from the IP Settings section) until the 

choice cycles to 

DHCP

. This action causes all fields in the IP Settings 

section (other than Host Name) to be greyed-out.   

Do not alter any of these remaining greyed-out fields in the IP Settings section. 
Once the panel is rebooted, these values are obtained by the unit and 
displayed in the 

DNS

 fields after power-up.

Consult the 

MVP-9000i Operation/Reference Guide

 for setting a Host Name.

Configuring the Card’s Wireless Settings

This section configures both the communication and security parameters from 
the internal wireless card to the WAP.
Once you have set up the wireless card parameters, you must configure the 
communication parameters for the target Master; see 

Master Connection

.

Consult the 

MVP-9000i Operation/Reference Guide

 for configuring the wireless 

card for unsecured access to the WAP.

Configuring The Wireless Card for Secured Access To the WAP

In the 

Protected

 

Setup

 page:

1.

Select 

Wireless Settings

.

2.

Enter the SSID information automatically by pressing the 

Site Survey

 

button.

3.

Select a 

WEP

 secured WAP from within the Site Survey page, and press 

the 

Connect 

button.

4.

Write down the SSID name, Current Key string value, and panel MAC 
Address information so you can later enter it into the appropriate WAP 
dialog fields in order to "sync-up" the secure connection. These values 
must be identically reproduced on the target WAP.

Consult the 

MVP-9000i Operation/Reference Guide 

for manually entering the 

SSID information.

Master Connection

The panel requires you establish the type of connection you want made 
between it and your master. In the 

Protected Setup

 page:

1.

Select 

System Settings

2.

Select 

Type 

to toggle between 

USB

 and 

Ethernet

.

3.

When using 

Ethernet

, press the listed 

Mode

 to toggle through the 

 

available connection modes:

  

4.

Select the 

Master Port Number

 to open the keypad and change this 

value. The default setting for the port is 

1319

5.

Set your Master Port and select 

Done

.

If you have enabled password security on your master, you need to set the 
username and password within the device.
6.

Select the blank field 

Username 

to open the keyboard.

7.

Set your Username and select 

Done

.

8.

Select the blank field 

Password

 to open the keyboard.

9.

Set your Password and select 

Done

.

10. Press the 

X

 button to return to the 

Protected Setup

 page.

11. Press the 

Reboot 

button to reboot device and confirm changes.

Touch Panel Calibration

In the 

Protected Setup

 page, follow these steps:

1.

Select the 

Calibrate

 icon.

2.

Touch each target on the screen as they appear. Once calibrated the 
panel confirms and instructs you to touch the screen to continue.

Panel Intercom Configuration

Incorporating an intercom capable panel into your NetLinx 

 

system

Download the module for the intercom panel from 

www.amx.com

, and include 

it in your NetLinx project file. For searching purposes, the module 

manufacturer 

is 

AMX

 and the 

model

 is 

Intercom

.

Note

:

 

The intercom module will only work with AMX intercom capable panels.

Cleaning the Touch Overlay and Case

Always use a clean cotton cloth and a spray bottle containing water or a 
vinegar-based cleaner when cleaning the MVP-9000i, as alcohol-based 
cleaners can damage the device. 

Do not directly spray the device

: instead, 

spray the cloth to clean the touch screen overlay. Do 

NOT

 use an abrasive of 

any type to clean the MVP-9000i, as this may permanently damage or remove 
the device’s finish.

Battery Life and Replacement

The battery powering the MVP-9000i is designed for upwards of 300 deep 
discharge rechargings. Regular shallow rechargings will extensively increase 
expected battery life, and the device should be stored in either a Table 
Charging Station or Wall Charging Station when not in use to keep it at an 
optimum charge. The battery has reached its effective end of life after it can no 
longer hold more than a 70 percent charge.

Proper Battery Maintenance

NOTE: To insure maximum performance and reliability of your AMX 
Wireless Touch Panel, please insure that a full charge is performed every 
3 months if not used regularly. If a battery is left uncharged beyond this 
time frame, it may result in premature battery lifespan degradation and 
will require replacement.

Connection Modes

Mode Description

Procedures

Auto

The device connects to the first 
master that responds. This 

 

setting requires that you set 
the System Number.

Setting the System Number:
1. Select the System Number to open the 
keypad.
2. Set your System Number and select 

Done

.

URL

The device connects to the 
specific IP of a master via a 
TCP connection. This setting 
requires that you set the Mas-
ter’s IP.

Setting the Master IP:
1. Select the Master IP number to the 
keyboard.
2. Set your Master IP and select 

Done

.

Listen The device "listens" for the 

master to initiate contact. This 
setting requires you provide 
the master with the device’s IP.

Confirm device IP is on the Master URL 
list. You can set the Host Name on the 
device and use it to locate the device on 
the master. Host Name is particularly 
useful in the DHCP scenario where the IP 
address can change.