Installing Tabletop (MXT) Panels
42
Modero X® Series G4 Touch Panels Instruction Manual
MXT-1000 / MXT-700
Detailed specifications drawings for the
MXT-1000
and
MXT-700
are available to download from www.amx.com.
Connector Locations - MXT-1000/MXT-700
Two Type A USB ports are located on the rear right corner of the panel (FIG. 18). USB peripherals (i.e. mouse,
keyboard) may be connected to either of the two USB ports on the rear of the device. Updates to the device’s firmware
can also made via the USB ports (see
Upgrading Firmware via USB Flash Drive
on page 41 for details). Note that
FIG. 18 shows the MXT-1000, but the USB ports are in a similar location on the MXT-700.
Power via 12 VDC
The MXT-2000XL-PAN and MXT-1900L-PAN use a 12 VDC-compliant power supply to provide power to the panel via
the 2-pin 3.5 mm captive wire PWR connector. The incoming PWR and GND wires from the power supply must be
connected to the corresponding locations within the PWR connector.
Wiring a 12VDC Power Connection
To use the 2-pin 3.5 mm captive wire connector with a 12 VDC-compliant power supply, the incoming PWR and GND
wires from the external source must be connected to their corresponding locations on the connector (FIG. 19). The
connector uses locking screws to insure a connection to the device, so make sure to insert and tighten the screws before
applying power.
1.
Insert the PWR and GND wires on the terminal end of the 2-pin 3.5 mm captive wire cable.
Match the wiring locations of the +/- on both the power supply and the terminal connector.
2.
Tighten the clamp to secure the two wires.
FIG. 18
MXT-1000 - rear view
USB Ports
Entry for RJ45/PoE Cable
Refer to the Power via PoE
section on page 43
for details on PoE and Ethernet Cable
Installation and Modification.
Connecting power to the panel should be done using the included 2-pin 3.5mm
captive wire connector included with the device. This connector is retained within its
port with locking screws instead of the pins on each side of standard captive wire
connectors, and using force to insert a standard captive wire connector may damage
the device.
FIG. 19
NetLinx power connector wiring diagram
PWR +
GND -
To the Touch Panel
Power Supply
Summary of Contents for MXD-430
Page 6: ...iv Modero X Series G4 Touch Panels Instruction Manual Table of Contents ...
Page 20: ...MXT D 2000XL PAN 20 3 X Series Panels 14 Modero X Series G4 Touch Panels Instruction Manual ...
Page 28: ...MXT D 1900L PAN 19 4 X Series Panels 22 Modero X Series G4 Touch Panels Instruction Manual ...
Page 36: ...MXT D 1000 10 1 X Series Panels 30 Modero X Series G4 Touch Panels Instruction Manual ...
Page 46: ...MXD 430 4 3 X Series Panels 40 Modero X Series G4 Touch Panels Instruction Manual ...
Page 50: ...Installing Tabletop MXT Panels 44 Modero X Series G4 Touch Panels Instruction Manual ...