Installing Tabletop (MXT) Panels
43
Modero X® Series G4 Touch Panels Instruction Manual
Do not tighten the screws excessively; doing so may strip the threads and damage the connector.
3.
Verify the connection of the 2-pin 3.5 mm captive wire to the external 12 VDC-compliant power supply and apply
power.
Power via PoE
Power for the MXT-1000 and MXT-700 is supplied via PoE (Power Over Ethernet ), utilizing an AMX-certified,
capacitive touch-compliant PoE injector such as the PS-POE-AT High Power PoE Injector (
FG423-81
) or other
approved AMX PoE power source.
The incoming Ethernet cable should be connected to the RJ45 port on the cable attached to the device.
Ethernet Cable Installation and Modification
In tabletop installations where concealing the Ethernet cable is desired, a hole at least 1.00” (2.54 cm) in diameter is
required in the surface to allow passage of the female RJ45 connector (FIG. 20). If using a smaller hole is unavoidable,
you will need to disconnect the Ethernet cable (
ECA5968-05
) from the device, to feed the male end of the cable through.
To disconnect and reconnect the Ethernet cable on the MXT-700 and MXT-1000 to allow use of a hole smaller than
1.00” in diameter:
1.
On a soft surface, turn the MXT-1000 face-down to access the bottom of the device.
2.
Remove the clamp holding the Ethernet cable (FIG. 20).
3.
Remove the Ethernet cable connector and pull the cable out of the clamp.
4.
Pass the Ethernet cable (
ECA5968-05
) through the hole, with the RJ45 connector on the other side of the
installation surface from the device.
5.
Press the Ethernet cable back into the clamp.
Do NOT tighten the clamp at this time.
6.
Using a non-conductive item such as a wooden stick, reinsert the Ethernet cable connector into the device. Ensure
that the connector is properly seated.
7.
Tighten the clamp to secure the Ethernet cable.
Make sure the clamp is around the bundled black cable, not the individual wires
8.
Connect the RJ45 connector to its incoming Ethernet cable and apply power.
FIG. 20
Bottom of the MXT-700/1000
Ethernet Cable
Connector
Clamp
The minimum diameter hole through which the Ethernet cable may pass is 0.50"
(1.27 cm).
Summary of Contents for MXD-430
Page 6: ...iv Modero X Series G4 Touch Panels Instruction Manual Table of Contents ...
Page 20: ...MXT D 2000XL PAN 20 3 X Series Panels 14 Modero X Series G4 Touch Panels Instruction Manual ...
Page 28: ...MXT D 1900L PAN 19 4 X Series Panels 22 Modero X Series G4 Touch Panels Instruction Manual ...
Page 36: ...MXT D 1000 10 1 X Series Panels 30 Modero X Series G4 Touch Panels Instruction Manual ...
Page 46: ...MXD 430 4 3 X Series Panels 40 Modero X Series G4 Touch Panels Instruction Manual ...
Page 50: ...Installing Tabletop MXT Panels 44 Modero X Series G4 Touch Panels Instruction Manual ...