Novara ControlPads
10
Novara ControlPads & KeyPads
Input Connector
FIG. 11 illustrates connecting the 1000 Series ControlPad to an external switch (such as a PIR switch), for detecting a
High to Low or Low to High state.
If for example a PIR is attached to the Input, this will act as a trigger to reset the internal inactivity timer for Time Out
routines.
Power Supply Connector
FIG. 12 illustrates connecting the 1000 Series ControlPad to the included power supply.
Connect the White strip lead to the +VE terminal on the ControlPad,
Connect the Black strip lead to the –VE terminal.
When the ControlPad is powered up or a program downloaded, button #2 will flash for 2 seconds then extinguish to
indicate that the ControlPad has passed it’s self-test.
FIG. 11
Input Connector
PIR Switch
GND
Input State
SHARED 12V
If using an AMX Power Supply with a 2-pin phoenix connector (not included), be
aware that the Power Supply polarities on Novara ControlPads are opposite to that of
other AMX equipment. This is not issue if using the included 10-pin connector.
FIG. 12
Power Supply Connector
Power Supply
SHARED 12V