System Status Page
74
RMS - Administrator’s Guide
Device Parameter Page
Parameter information attributed to a device monitored by the RMS application is listed in the
Device
Parameter
page (FIG. 68).
FIG. 68
Device Parameter Page
Parameter Settings
• Name
The name of the parameter being monitored.
• Current Value
The value of the parameter
• Threshold Operator
The threshold value is the value for which this parameter is considered to indicate
a problem or fault. The comparison operator is used to detect when the value
changes from the un-faulted to the faulted condition.
• The comparison operators "Less Than", "Less Than or Equal To", "Greater
Than", "Greater Than or Equal To", "Equal To", and "Not Equal To" can be used
for string and number parameters.
• The comparison operators "Contains" and "Does Not Contain" are primarily
used for string parameters.
Example:
"Lamp Hours" might have a threshold value of 1000 and any value
over this would require maintenance. The comparison operator would then be
"Greater Than".
• When this parameter changes from a value that is not greater than 1000 to a
value that is greater than 1000, the parameter will faulted.
• When the value changes from a value greater than 1000 to a value not greater
than 1000, the fault status is cleared.
• Threshold
The threshold value
Summary of Contents for RMS
Page 24: ...RMS Resource Management Suite 12 RMS Administrator s Guide ...
Page 58: ...RMS Configuration Wizard 46 RMS Administrator s Guide ...
Page 72: ...RMS Administration 60 RMS Administrator s Guide ...
Page 78: ...RMS Hotlist 66 RMS Administrator s Guide ...
Page 170: ...Reporting Page 158 RMS Administrator s Guide ...
Page 182: ...Configuration Page 170 RMS Administrator s Guide ...
Page 186: ...Help Page 174 RMS Administrator s Guide ...
Page 188: ...Sitemap Page 176 RMS Administrator s Guide ...
Page 211: ...RMS Touch Panel Pages 199 RMS Administrator s Guide ...