P·20
WARNING!
In order to guarantee the quality of the electric wheelchair, please
contact your dealer to replace the spare parts such as batteries,
tyres, controller, motors and charger. Maintenance must be carried
out by the dealer.
LED*
Anomaly Diagnosis
Breakdown location
1 LED lit
Week battery
Charge the battery.
2 LEDs lit
Left motor anomaly
Check the motor and its connections.
3 LEDs lit
Left brake anomaly
Check that the brake lever is in the correct
position and if the braking is damaged.
4 LEDs lit
Right motor anomaly Check the motor and its connections.
5 LEDs lit
Right brake anomaly
Check that the brake lever is in the correct
position and if the braking is damaged.
6 LEDs lit
Control box overload Check if the brake is removed and if the wheels
are locked.
7 LEDs lit
Joystick anomaly
Check that the joystick is in the central position.
8 LEDs lit
Control box anomaly Control box malfunction.
9 LEDs lit
Control box anomaly Control box malfunction.
VII. DIAGNOSIS & TROUBLE-SHOOTING
For your convenience, this product has an automatic fault warning function. In the event of a
malfunction, the indicator lights on the controller flash and the horn sounds. You can identify
a fault using the information in Table. If the problem persists after inspection of the fault, do
not use the wheelchair. Turn it off and contact your dealer.
VIII. SAFETY DEVICES AND ACCIDENT
MANAGEMENT
• Fuse: please refer to 6.1.4 Surge protection
• Safety belt: please refer to 6.1.6 Safety belt
• Release the joystick in case of failure: the wheelchair will stop
* Joystick with remote control option