AMYPOWER ALLTRACK R3 & R SERIES - Owner’s Manual (Rev. A)
17
IX. OPERATING GUIDE
A. CIRCUIT BREAKERS
Your Amypower Alltrack has a single circuit breaker.
In the unlikely event of a short circuit or heavy overload, all
power to your chair will be shut off.
To reset your chair, depress the circuit breaker button. A few
minutes wait is required before the circuit breaker will reset.
To access the circuit breaker
Push the battery box panel when pulling the handle.
Drop the panel down and the circuit breaker becomes
visible (a).
Reset the circuit breaker.
Lock the panel back in its upright position.
Repeated Shutdown:
If the chair continues to shut down after resetting, have it
serviced by a supplier.
B. JOYSTICK ASSEMBLY
The joystick connects to a controller, which controls the
chair’s performance. The joystick varies based on the
option selected for you.
1.
VR2 Joystick *
2.
R-Net (Option)*
*Please refer to the user’s manual provided with information
package.
C. ENHANCED DISPLAY
Please refer to the PG Drives Enhanced Display owner’s
manual.
D. MOTOR LOCKS
Disconnect the motor locks when you need to manually
push the chair, for example when in an emergency, or
if batteries fail.
WARNING
1.
Do not disengage motor locks unless power to the chair is
off.
2.
Be aware that the chair will not have brakes in the free-
wheel position.
3.
Make sure that the person pushing the chair has full control
when motor locks are disengaged.
1.
To Disengage Motor Locks:
Turn the lever (A) towards the front of the chair to disengage the
motor lock.
2.
To Engage Motor Locks:
Turn the lever (A) towards the center of the chair to return to the
drive position.
NOTE- If the lever is difficult to disengage, rock the wheelchair
slightly from front to rear and/or push against the chair while moving
the lever.
a
VR2
R-Net
A