64
When the lubricant in the reservoir has fallen to the minimum level it must be refilled.
Generally a filler pump is used for this purpose. The procedure is as follows:
•
With a new filler pump (or filling hose) the hose should first be primed with lubricant.
This avoids the pumping of air into the reservoir. For this ball (1) in the snap-on
connector on the filler hose should be depressed while pumping lubricant through
the hose until it is filled with the lubricant
•
Remove the dust cap from the filler connector
•
Carefully clean the filler connector and the connector on the filler hose
•
Secure the filler hose to the filler connector
•
Fill the reservoir to not more than the maximum level (2 cm below the top of the
reservoir) or until the follower plate meets its stop
•
Replace the dust cap on the filler connector
•
There is a filter within the filler connector in the reservoir. If pumping is very difficult
the filter could be blocked. In this case, dismantle and clean the filter.