September 2012
L010155
39
P - Absolute Position and Analog Position
Format 1:
P[value]
Description: This command calculates and sets the number of clocks for the DPN10601
to send out following a G command. Motion is not activated by this command; it only sets
the register. (N = P - Z)
Range:
-8388607 to +8388607
Format 2:
P
Description: This command uses the voltage on input 1 to calculate and set the number
of clocks for the DPN10601 to send out following a G command. The analog position must
be enabled for this command to work. Motion is not activated by this command, it only sets
the register (N = P - Z). This command is used in conjunction with the analog position “:”,
the analog position lower limit “{“, and the analog position lower limit “}” commands.
S - Go Slew
Format:
S
Description: This command will send clocks out to the DPN10601. The only commands
that can stop the clocks are; “.” (stop motion) or “,” (soft limit). Motion can also be stopped
by using the limit switch inputs. The ramp profile is specified by the B (base speed), M (max
speed), and A (acceleration/deceleration) commands.
T - Motor Current Enabled
Format 1:
T[0 or 1]
Description: This command will control the On/Off output, which is designed to connect to
the on/off input of Anaheim Automation’s step motor drivers. To energize and allow current
to flow through the coil of the motor, set the value to 1. To de-energize and turn the current
off to the motor, set the value to 0. This is a dedicated output, and not controlled with the
output register.
July 2018