33
Meaning: This message will appear if the safety reversing sensors are out of
alignment, if they are blocked or if the wiring is disconnected. To clear message from
door control do the following:
• Check to see that area is clear between the safety reversing sensors.
• Check to see that the safety reversing sensors are not misaligned.
• Realign receiving eye sensor, clean lens and secure brackets.
• Verify door track is firmly secured to wall and does not move.
• Check to see that the safety reversing sensors wires are connected to the motor unit.
• If message has not cleared after the above checks, refer to message #2.
Meaning: This message will appear if the safety reversing sensors are miswired.
To clear the message, do the following:
•
Inspect the safety sensor wires for a short (staple in wire), correct wiring polarity
(black/white wires reversed), replace/attach as needed.
• Disconnect all wires from back of motor unit.
•
Remove safety reversing sensors from brackets and shorten sensor wires to 1-2 ft.
(30-60 cm) from back of each sensor.
•
Reattach sending eye to motor unit using shortened wires. If sending eye indicator light
glows steadily, attach the receiving eye.
•
Align sensors, if the indicator lights glow replace the wires for the sensors. If the sensor
indicator lights do not light, replace the safety reversing sensors.
Meaning: This message will appear when the Prog <LEARN> button has been
pressed on the door control. Pressing the Prog <LEARN> button again will allow the
user to program an additional remote control to the opener.
Meaning: This message will appear when the Prog <LEARN> button has been pressed
a second time on the door control or anytime on the opener. The opener is ready to
program another remote control by simply pressing the remote control button. Once
the opener has ‘LEARNED’ the remote control, the worklight will blink one time.
Meaning: This message will appear when the ‘LOCK’ button has been pressed and
held for more than one second. This feature will disable the opener from receiving
remote control signals. To exit ‘LOCK’ mode, press and hold the button for more than
one second.
Meaning: This message will appear when the ‘LANGUAGE’ button has been pressed.
Pressing the button will toggle to the next language.
Meaning: This message will appear when the ‘MOTION SENSING’ button is pressed.
The Motion Detector will toggle on or off with each press of the button.
Meaning: Opener is running on battery power.
Meaning: Opener is running on battery power with full charge.
Meaning: Opener is running on battery power with low charge.
Meaning: Battery is beyond a recoverable condition.
Meaning: Battery charging from recent battery backup state.
SAFETY SENSORS
MALFUNCTION. CHECK
MISWIRING. SEE
OWNER’S MANUAL.
Message
Message
Smart Control Panel
®
Messages
The following messages are contained within the Smart Control Panel
®
and may appear during the operations of the unit:
SAFETY SENSORS
CHECK ALIGNMENT,
BLOCKAGE OR
MISWIRING. SEE
OWNER’S MANUAL.
LEARN REMOTE
CONTROL. PRESS
LEARN BUTTON TO
CONFIRM.
LEARN MODE.
PRESS REMOTE
CONTROL BUTTON TO
PROGRAM REMOTE.
LOCK MODE. REMOTE
CONTROL LOCKED OUT.
PRESS LOCK BUTTON
TO ENABLE REMOTE.
Message
Message
Message
Message
Message
ENGLISH, FRANÇAIS
AND ESPAÑOL.
MOTION SENSING ON,
MOTION SENSING OFF.
BATTERY BACKUP
ENABLED.
BATTERY BACKUP
ENABLED.
BATTERY LOW BATTERY
BACKUP ENABLED.
POWER RESTORED
BATTERY CHARGING.
BATTERY BAD REPLACE
BATTERY NOW SEE
OWNER’S MANUAL.
Message
Message
Message
Message
Message
Summary of Contents for Security+ 3850AD