ADV7181B
Rev. B | Page 43 of 100
ADVANCE TOGGLE OF
FIELD BY NFTOG[4:0]
DELAY TOGGLE OF
FIELD BY NFTOG[4:0]
NFTOGSIGN
ODD FIELD?
0
1
NO
YES
NFTOGDELE
ADDITIONAL
DELAY BY
1 LINE
1
0
NFTOGDELO
ADDITIONAL
DELAY BY
1 LINE
1
0
FIELD
TOGGLE
NOT VALID FOR USER
PROGRAMMING
04984-024
Figure 24. NTSC Field Toggle
Table 56. Recommended User Settings for PAL (see Figure 26)
Register Register
Name
Write
0x31
Vsync Field Control 1
0x1A
0x32
Vsync Field Control 2
0x81
0x33
Vsync Field Control 3
0x84
0x34
Hsync Pos. Control 1
0x00
0x35
Hsync Pos. Control 2
0x00
0x36
Hsync Pos. Control 3
0x7D
0x37 Polarity
0xA1
0xE8 PAL_V_Bit_Beg
0x41
0xE9 PAL_V_Bit_End
0x84
0xEA PAL_F_Bit_Tog
0x06
NFTOGSIGN NTSC Field Toggle Sign, Address 0xE7[5]
Setting NFTOGSIGN to 0 delays the field transition. Set for
user manual programming.
Setting NFTOGSIGN to 1 (default) advances the field
transition. Not recommended for user programming.
NFTOG[4:0] NTSC Field Toggle, Address 0xE7[4:0]
The default value of NFTOG is 00011, indicating the NTSC
field toggle position.
For all NTSC/PAL field timing controls, both the F bit in the
AV code and the Field signal on the FIELD pin are modified.