GENERAL SPECIFICATIONS 

Table 1. 

 

 

Altitude

 

<2000m 

Fuse

 

100mA/60V resettable fuse 

Sampling Rate

 

Approx.3 times/sec

 

Power Source

 

5# Battery LR6 (1.5V) ×6 (or External AC Adapter) 

Power Consumption

 

<650mW

 

Lower Battery Indication

 

The LCD display “

” symbol

 

Over Range Indication

 

Displays “1” when exceeding upper limit. 

Additional Temperature Coefficiency

 

0.15 × Specified Accuracy/

 (<18

 or >28

Operation Environment

 

Temperature: -15

-55

 

Relative humidity: <75%RH 

Storage Environment

 

Temperature: -40

-60

 

Relative humidity: <90%RH 

LCD Size

 

84.8×59.8mm, Max.Display 1999

 

Dimension

 

175 (L) × 110 (W) × 62.5 (D) mm 

Weight

 

580g (including battery)

 

TECHNICAL SPECIFICATIONS   

 

Table 2.

  

Basic Function 

Range 

Basic Accuracy 

Output Voltage 

250V/500V/1000V 

±10% 

Testing Current 

250V(R=250k

)  1mA 

500V(R=500k

)  1mA 

1000V(R=1M

)  1mA 

±10% 

Insulation Resistance 

250V: 1M

 - 200M

 

500V: 1M

 - 200M

 

1000V: 10M

 - 2000M

 

±(4%rdg±2d) 

Short Circuit Current 

<1.8mA 

 

Median Resistance 

250V/500V: 2 M

 

1000V: 5M

 

 

Resistance and Continuity Test 

0

 - 2k

, <50

 Beeper Alarm, 

Testing Current 1mA 

±(0.8% rdg6d) 

DCV Test 

0V~1000V 

±(0.5% rdg+6d) 

ACV Test 

0V~750V 

±(1% rdg+6d) 

Terminal Position 

Insulation resistance: E and L 

Voltage/Current: V/

 and G 

 

Voltage Input Impedance 

1M

 

 

Summary of Contents for VC60B

Page 1: ...tronic equipments electric facilities etc DESCRIPTION VC60B 1 0 is a digital insulation tester which adopts DC voltage converter of low consumption and high converter ratio inductance energy storage to convert the voltage of 9Vdc into 250V 500V 1000Vdc With digital bridge the instrument has the features of being easy to operate wide test range highly stable performance backlit LCD display data hol...

Page 2: ...r 28 Operation Environment Temperature 15 55 Relative humidity 75 RH Storage Environment Temperature 40 60 Relative humidity 90 RH LCD Size 84 8 59 8mm Max Display 1999 Dimension 175 L 110 W 62 5 D mm Weight 580g including battery TECHNICAL SPECIFICATIONS Table 2 Basic Function Range Basic Accuracy Output Voltage 250V 500V 1000V 10 Testing Current 250V R 250kΩ 1mA 500V R 500kΩ 1mA 1000V R 1MΩ 1mA ...

Page 3: ... terminal for tested circuit 4 L Terminal for connection to the GND of the tested object 5 G Protection terminal When the tested object is required to add the protection loop to eliminate the leakage effect connect the electrode wire of the protection loop to G terminal 6 Voltage measurement resistance measurement 2kΩ and continuity measurement input terminal V Ω 7 Test button 8 High voltage indic...

Page 4: ...the ground terminal of the tested object Lead E is required to be hung in the air 6 If the LCD displays 1 it indicates over range operation Please choose a higher range to get reading Caution 1 Pressing the TEST button output terminal E will have high voltage output Be careful to avoid electric shock 2 Before testing make sure to choose a correct voltage range Make sure the LCD display is in accor...

Page 5: ... the instrument circuit 3 During high voltage circuit measurement do not touch the high voltage circuit to avoid electric shock DATA HOLD Press the HOLD button the current data will be held on the LCD Press the HOLD button again to cancel data hold Note There is no data hold function during insulation resistance measurement BACKLIT DISPLAY Pressing button the LCD backlight turns on Pressing button...

Page 6: ...d replace with a new one To ensure long time battery power supply it is recommended to use alkaline batteries 3 Load the battery door and tighten the screws PACKING LIST 1 Digital insulation tester x1pcs 2 10A test lead x1 pair 3 5 battery 1 5V x6pcs 4 Operation manual x1pcs 5 Shoulder strap x1pcs 6 Crocodile clip x1 pair TROUBLE SHOOTING If the instrument does not work properly the following self...

Page 7: ...e is not necessarily performed except those mandated by government requirements 3 Customers are responsible for their applications using ATI components In order to minimize risks associated with the customers applications adequate design and operating safeguards must be provided by the customers to minimize inherent or procedural hazards ATI assumes no liability for applications assistance or cust...

Reviews: