TROUBLE SHOOTING 

If the meter does not work properly, check the meter as followings. 

Table 14. 

 

 

 

 

 

 

ORDERING INFORMATION 

Table 15. Unit Price 

            Part# 

1-2 

VC97 

$26.87 $25.87 

Note: If you buy 5 or more, please contact us for a better price. 

NOTICE 

1.

 

ATI reserves the right to make changes to its products or to discontinue any product or service without notice, and advise 
customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied 
on is current and complete.   

2.

 

All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgment, including 
those pertaining to warranty, patent infringement, and limitation of liability. Testing and other quality control techniques are 
utilized to the extent ATI deems necessary to support this warranty. Specific testing of all parameters of each device is not 
necessarily performed, except those mandated by government requirements.   

3.

 

Customers are responsible for their applications using ATI components. In order to minimize risks associated with the 
customers’ applications, adequate design and operating safeguards must be provided by the customers to minimize inherent 
or procedural hazards. ATI assumes no liability for applications assistance or customer product design.   

4.

 

ATI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, 
mask work right, or other intellectual property right of ATI covering or relating to any combination, machine, or process in 
which such products or services might be or are used. ATI’s publication of information regarding any third party’s products 
or services does not constitute ATI’s approval, warranty or endorsement thereof.   

5.

 

IP (Intellectual Property) Ownership: ATI retains the ownership of full rights for special technologies and/or techniques 
embedded in its products, the designs for mechanics, optics, plus all modifications, improvements, and inventions made by 
ATI for its products and/or projects.   

 

 

 

 

 

 

 

 

 

Conditions Solution 

No Display 

 

Power is off 

 

HOLD key 

 

Replace battery 

 Symbol Display 

 

Replace battery   

Big Error 

 

Replace battery 

Summary of Contents for VC97

Page 1: ...nce frequency temperature etc DESCRIPTION VC97 is a high performance high accuracy 3 3 4 digit 32mm digit high by LCD displaying meter The function includes DCV ACV DCA ACA resistance capacitance freq...

Page 2: ...rature 10 50 Relative humidity 80 RH Power 2pcs 1 5V AAA 7 battery Dimension 185 L 93 W 35 H mm Weight Approx 290g including battery Accessories Manual gift box holster TP01 temperature probe test lea...

Page 3: ...0A less than 15sec Overload Protection 0 5A 250V fuse 13A 250V fuse Frequency Response 40 100Hz under 10A range 40 400Hz at other range Table 6 Resistance Range Accuracy Resolution 400 0 8 5 0 1 4k 0...

Page 4: ...5 4 0 001Hz 100Hz 0 01Hz 1000Hz 0 1Hz 10kHz 1Hz 100kHz 10Hz 1MHz 100Hz 30MHz 1kHz Input Sensor 0 7V Overload Protection 250V DC AC peak value Table 9 hFE Range Accuracy Test condition hFE NPN or PNP 0...

Page 5: ...ange key Select auto range or manual range 2 6 DC AC key Select DC AC mode 3 Knobe Change measuring function and range 4 Temperature jack 5 Voltage Current Resistance Frequency GND jack 6 Battery case...

Page 6: ...on switch to A range press DC AC key to select AC working mode connect the test leads across to the circuit under tested the current value and polarity of the point which red lead connect will display...

Page 7: ...and the black one to the approx forward voltage of this diode will be displayed on LCD 4 Backward measurement connect the red test lead to the of the diode and the black one to and LCD will displayed...

Page 8: ...he circuit boards and case and can cause the multimeter to work improperly although the holster can provide enough protection 8 Wipe the multimeter with a damp cloth occasionally to keep it looking ne...

Page 9: ...ers of each device is not necessarily performed except those mandated by government requirements 3 Customers are responsible for their applications using ATI components In order to minimize risks asso...

Reviews: