AMD5x Passive Infeed Unit and AMD5x Servo Drive - User Guide
ANCA MOTION
D-000129 Rev 09
100
implemented
Excess lengths of Hiperface DSL motor cables are not coiled
Hiperface DSL motor cables are separated from each other
No power factor compensation capacitors have been connected to the motor cable.
A sinusoidal filter has been installed in between the motor armature output on the drive
and the motor if required by the application.
All low voltage control cables have been correctly connected and are secure.
External References required by the Drive IO Interface have been correctly connected
and are secure.
There is no dust or other foreign object inside the drive after installation (e.g. Due to
cutting of cables etc.).
All wiring conforms to applicable regulations and standards.
Insulation of power wiring has been tested. See
Checking the Insulation of the
No physical damage is present to any component within the system.
The drive and all equipment connected to the motor is ready for start-up.
A risk assessment has been completed on entire machine and is considered by the
user to be safe for operation.
Regeneration energy and power has been assessed and external resistor has been
connected (see
There are no shorts between encoder power supplies and encoder GND.
The mains supply voltage is within the limits of operation of the drive. See
Summary of Contents for AMD5x Series
Page 12: ......