9.2 Enable pressure switch/meter
Using [Browse/Menu] key into main menu, choose
【
Set up valve
】
,
【
Enter/Save
】
key to confirm, push up/down key or
【
Browse/Menu
】
browse into
【
Valve
on/off check
】
, and
【
Enter/Save
】
to confirm. Push
【
Browse/Menu
】
key will
show choice between
【
Enable
】
and
【
Disable
】
, choose one and push
【
Enter/Save
】
key to confirm. Then the LCD will show “Saving”, and a beep,
which means done with saving.
9.3 Pressure check delay
Water pressure takes time to establish, so there must have a time delay to check the
water pressure to avoid misalarm. Out of factory default is 1 minute, user can adjust
up to 99 minutes to make sure there is no misalarm. After setup delay time, push
【
Enter
】
to save.
9.4 Valve drive level setup
This set is for making drive 6-12V latching valves more realible.
We divide solenoid pulse width into three ranges: 1-20 ms; 2-50 ms; 3-100 ms.
For 6V latching valve, recommend 20 ms.
For 12V latching valve, recommend 50 ms or 100 ms.
User can adjust the range until fit according to the real valve at real time.