ANC Technology
7
moisture sensor is been registered, the controller will control valve only.
If not setup Dry/Wet control yet, or the setup is not right, there will be a reminder of
failure. The system will not working until this setup is been fixed. Push
【
Menu
】
key into adjusting Dry/Wet control, adjusting them until right.
Note:
Wet control % must bigger than Dry control %.
4. How to establish wireless mesh network communication
After power been turn on, if moisture sensors and valves are already been registered,
the controller will automatically try to establish wireless communication route to
reach main controller. During searching time, keys been locked, LCD shows
“Searching Comm path”. After route is been established, there will be two beeps,
the controller is ready for work.
If failed to establish the route, the controller will unlock the keys and back after 1
minute. Push
【
+
】
and
【
-
】
keys to check route, you will see XX, which means no
route been established. Push and hold
【
Enter/Save
】
and
【
Exit/Delete
】
keys at
same time to speed up research, otherwise the controller will try automatically again
and again until done.
After successfully established route, the field controller will send the route
information to main controller and show on the main controller screen as following
that is for sensor.
If the search is not successful, the field controller will keep try every 1 minute.