ANC Technology
9
from sleep status to total turn off.
After been total turn off, the solar panel will still charge the battery as long as there
is sun. System will do auto-restart after the battery is recharged back.
7. Manually open/close valves
Can manually on/off valves from main controller.
Or do manual operation directly on the field controller when it is on. Push
key with valve logo to realize manually open/close valves. On LCD screen, there
has
【
Manual
】
→
【
Auto
】
→
【
Manual
】
→
【
Auto
】
, loop operation.
Also can manually open/close valve by using Remoter (Romoter-1) for the
convenience of mainterance.
If user did manual open/close, the valve will keep open/close until main controller
or wireless field controller change the status back to
【
Auto
】
. Or setup timer to
stop.
Remark: Manual operation has priority over Lock out period.
8. Manually open/close valves
On control panel, choose and push
【
#1
】
, LCD will show “Manual on”
,
push
again, show “Auto off”
,
push again, show “Manual off”
;
Push again, show “Auto
off”. So to circle.
User can remote control open/close valves from main controller or cell if you use
3G/WIFI system.