16
This function is for fertilizing control by total flow volume. Customer setup first and second
alarm volume from main controller or PC. For example, like 3 cubic meter and 4 cubic meter.
Then, when the volume reached 3 cubic meter, first alarm on, it is time to start get ready to
turn off the valve, when reached 4 cubic meter, second alarm on, it is time to turn off the
fertilizing valve.
After valve been turned off, flow rate reach to 0, this flow meter controller will automatically
finish this cycle of fertilizing alarm.
Suggested connection:
4
,
Current pressure meter reading
5.7.2 LCD display for protective shut down of pump
:
When pump is been protective shut down, LCD will show the reason, 1, High flow rate +
value of the high flow rate; 2, Low flow rate + value of the low flow rate; 3, High pr
value of high pressure; 4 Low pr value of low pressure; 5, Low water level.
Above example show information as, auto shut down by low flow rate at 0.00 m³/h.