25
6.3.1 Register and remove pump
Reference 6.1.1 flow meter registration and remove.
6.3.2 Set up pump protection sensor
Browse into “Set up pump” menu, there are Disable flow meter, Pressure meter, Liquid level
switch 4 choices as following:
In the Sensor option to choose, if choose 0, which means no protection for the pump. If
choose like above, 1 and 2, which means choose flow meter and pressure sensor as
protective sensors.
( Flow meter protection
:
Through time delay to setup right flow rate range. If the flow rate is out of range during
normal operation after delay time, this controller will protectively turn off the pump.
Jammed, or broken pipe could be the reason. If there is false alarm, adjusting the setup.
( Pressure meter protection
:
Through time delay to setup right pressure range. If the pressure is out of range during
normal operation after delay time, this controller will protectively turn off the pump.
Jammed, or broken pipe could be the reason. If there is false alarm, adjusting the setup.
( Level sensor protection
:
The level sensor will first check if the water level reach high level before open the pump to
prevent open pump without much water. During normal operation, if the sensor detected low
Summary of Contents for FMP-Solar