22
Remove simultaneously
:
Remove registration information from main controller and FMP controller simultaneously.
Let FMP controller get ready for remove same as above. When FMP controller start to search
main controller, let main controller also into remove menu and get ready. Then the
registration information will be removed from both simultaneously.
Suggest to remove both simultaneously!
6.1.2 How to setup flow meter coefficient number
Browse into“
Flow meter coefficient
”menu, LCD will show current coefficient # as
following if there is one
:
Push digital keys to input, push
【
Exit
】
to delete one digital
,
automatically out after reach 8
digits
;
Less than 8 digits push
【
Enter
】
key to save. LCD will show saving and beep two times
to confirm.
Should get the coefficient # from the manual of the flow meter. Make sure input right to
avoid calculation error. If you know how to do it, you also can adjusting the efficient number.
(If the reading is bigger than real, increase the efficient #, otherwise reduce until read right).
6.1.3How to setup flow rate range
Browse into “
Setup flow rate range
”menu, LCD will show current flow rate range as