— 18 —

Range Hood Assembly

Number Part

1

LED light puck

2

Baffle filter

3

Panel

4

Rubber

5

Rubber strip

6

Blower

7

Switch wire

8

Switch bracket

9

Switch box

10 

Switch

11

Switch panel

12

Glass

13

Housing set

14

Hook

15

Outlet

16

Power cord

17

Electrical box base

18

PCB

19

Capacitor

20

Electrical box cover

21

Outer chimney

22

Inner chimney

23

Outer chimney bracket

24

Inner chimney bracket

Summary of Contents for GCT436

Page 1: ... GCT436 User Manual Installation Instructions IMPORTANT SAFETY INSTRUCTIONS Carefully read the important information regarding installation safety and maintenance Keep these instructions for future reference MAAN1177 01 ...

Page 2: ...SUMERS Start Here Safety Instructions are on pages 4 and 5 and Operating Instructions are on pages 16 and 17 Please perform these steps 1 Read the safety instructions 2 Read all instructions in the manual BEFORE operating the range hood 3 Remove all packing materials 4 Installation is to be done by a qualified technician only However the ultimate responsibility for proper installation falls to the...

Page 3: ...eparations 12 Step 7 Installing the Hood Mounting Bracket 12 Step 8 Installing the Upper Chimney Bracket 12 Step 9 Installing the Glass 12 Step 10 Installing the Damper 13 Step 11 Mount Range Hood Onto Wall 13 Step 12 Connect Ductwork 13 Step 13 Install Chimney 14 Step 14 Connect to AC 14 Step 15 Install Filters 15 Operation 16 Power Settings 16 Timer Function 16 Lights 16 Maintenance 17 Replacing...

Page 4: ...he service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Clean grease laden surfaces frequently To optimize performance and to disperse air properly make sure to vent air outside DO NOT vent exhaust into spaces between walls crawl spaces cei...

Page 5: ...UATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be burned c DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result d Use an extinguisher ONLY if 1 You know you have a Class A B C extinguisher and you already know how to operate it 2 The fire is small and contained in the area where it is started 3 The fire department is being called 4 You ...

Page 6: ...ry constructions and wall material Please consult your installation specialist regarding the optimal type of mounting screws and wall anchors to suit your home s construction 4 x Damper Screws 4 x Chimney Screws 4 x Screws Washers Installation of Glass Canopy 1 Filter Upper Chimney Lower Chimney Upper Chimney Bracket Lower Chimney Bracket Hood Mounting Bracket ...

Page 7: ... Speed Control Levels 3 Levels Interference Levels Radio Frequency Interference Protected Motors Single Motor Control Electronic Control Panel Filtration Stainless Steel Baffle Filters Illumination 2 x 2 55 W LED Venting Size Top Round 6 Inches 152 mm 10 8 275 mm 15 380 mm 19 6 500 mm 15 71 399 mm 36 914 mm 10 2 mm 19 37 75 480 mm 954 mm 19 mm Glass Depth 2 72 69 mm 12 305 mm ...

Page 8: ... 8 Mounting Brackets Upper Chimney Bracket Lower Chimney Bracket Mounting Bracket Hook ...

Page 9: ...bows and transitions will reduce the performance of the unit Each elbow is equivalent to 5 to 10 feet of straight run Proper size duct work should be 6 152 mm in diameter To reach a 9 foot ceiling make sure hood is installed 30 inches from cooking surface If you have a ceiling greater than 9ft please visit anconahome com to order a chimney extension If ductwork is already installed ensure ductwork...

Page 10: ... stove tops 4 Height of hood and duct cover For the most efficient quiet operation It is recommended that the range hood be vented vertically through the roof through 10 15 3 cm or bigger round metal aluminum vent work The size of the vent should be uniform Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than one elbow is used D...

Page 11: ...no less than 24 inch for electric cook tops and minimum of 30 inch for gas stove tops and no higher than 30 inch for electric cook tops It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high may be hard to reach and will lose its performance and efficiency If available also refer to stove top ...

Page 12: ...positioned flush with the top of the outside chimney See Figure 1 Screw upper and hood mounting brackets in tightly Fig 2 STEP 6 Preparations NOTE To avoid damage to your hood prevent debris from entering the vent opening Determine and mark the center line on the ceiling or wall where the range hood will be installed Make sure there is proper clearance within the ceiling or wall for exhaust vent D...

Page 13: ...oil tape Use caulking to seal exterior wall or roof opening around the cap STEP 10 Installing the damper Fix the damper on the top vent of hood with 4 screws See Figure 3 If ventilation system is equipped with an external air duct with a different diameter apply a reduction fitting However for maximum performance and safety a 6 round ducting is recommended Fig 3 STEP 11 Mount Range Hood Onto Wall ...

Page 14: ...DING INSTRUCTIONS This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded WARNING Improper grounding can result in a ...

Page 15: ...ain oil from baffles spacers filters oil tunnels oil containers before oil and residue overflow Remove all baffles spacers filters grease tray and oil containers and discard oil and residue Wash with warm soapy water NOTE Stainless steel baffles spacers and oil tunnel are top rack dishwasher safe Dry thoroughly before replacing and follow directions for installation in reverse Filters should be cl...

Page 16: ... lower speeds in succession until the motor stops working power off Timer Function uThe control module provides the option to run the motor for a predetermined time period in order to evacuate remaining vapors from the kitchen vPress the timer button while the motor is running The motor will shut off automatically after 3 minutes Lights u Press the light button to turn LED lights on and off 3 minu...

Page 17: ... the lights will slip out CAUTION BULB MAY BE HOT PLEASE TAKE OUT THE BULB WHEN THE BULB IS COMPLETELY COOL x Replace with a 4 Volt 2 5Watt max LED lights Do not touch replacement bulb with bare hands y Turn ON breaker and range hood to test for operation IMPORTANT ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY AT THE MAIN PANEL BEFORE CARRYING OUT ANY OPERATION ON THE APPLIANCE ...

Page 18: ...er strip 6 Blower 7 Switch wire 8 Switch bracket 9 Switch box 10 Switch 11 Switch panel 12 Glass 13 Housing set 14 Hook 15 Outlet 16 Power cord 17 Electrical box base 18 PCB 19 Capacitor 20 Electrical box cover 21 Outer chimney 22 Inner chimney 23 Outer chimney bracket 24 Inner chimney bracket ...

Page 19: ...Electrical Assembly Number Part 1 Electrical Box Base 2 PCB 3 Capacitor 4 Electrical box cover 5 Switch box 6 Switch Number Part 1 Blower 2 Wind Wheel Nut 3 Wind Wheel 4 Motor 5 Incabloc Rubber 6 Aluminum Cover 7 Plastic Wind Net 8 Sealing Gasket ...

Page 20: ...operating For optimal operation clean range hood and all baffle spacer filter grease tray oil container regularly Regular care will help preserve the appearance of the range hood Cleaning Exterior Surfaces Clean periodically with hot soapy water and clean cotton cloth DO NOT use corrosive or abrasive detergent e g Comet Power Scrub EZ Off oven cleaner or steel wool scoring pads which will scratch ...

Page 21: ...duct warranty by visiting the Ancona Home website Canada USA Phone 888 686 0778 Fax 800 350 8563 Email service anconahome com Website www anconahome com Ancona is in association with Mr Appliance for all after sales service calls Please contact their service provider or visit their website Phone 888 998 2011 Website www mrappliance com MAAN1177 01 ...

Reviews: