4
2.4. Precautions for installation
Confirm that there are no problems with the tools and instruments to be used before performing
work. Continued use of damaged or defective tools and equipment may cause serious accidents.
For safety, wear a helmet and safety shoes when working.
When placing a structure such as a truck scale on the load cell, place it slowly while checking safety.
Be careful not to get your fingers caught. If you sense any problems, suspend work temporarily and
confirm safety before restarting work.
2.5. Maintenance
Check the following items properly.
Is the gap of the swing stopper appropriate? Is it free of clogging from dirt, mud, etc.?
Is the pit free of water? (When installing the load cell in a pit)
Are the load cell and mounting brackets free of deposits?
Are the mounting bolts tight?
Is the stopper column tight?
Is there slack in the load cell cable?
Are cable connections tight?
Is the equipment free of electric leakage?
3. Introduction
The LCCD20 series compression type digital load cell is a high-performance compression type
double convex type digital load cell with rated capacity of 98.07 kN (10 t) to 294.2 kN (30 t) suitable
for truck scales.
Adjustment work can be done easily and quickly by combining with our indicator for digital load cells.
Since the load cell body is a sealed structure and compliant with IP68, it can be safely used in harsh
environments.
The compact design makes installation and maintenance work easy.
Caution
Because the load cell has excellent accuracy and responsiveness, consideration is required for the
structure and installation method of the equipment to be installed.
Please understand the contents of this manual in order to gain maximum performance, and install
correctly.