5
4. Specifications
Item CD
LCCD20T010-K
LCCD20T010N-K
LCCD20T010KEX
LCCD20T010NKEX
LCCD20T020-K
LCCD20T020N-K
LCCD20T020KEX
LCCD20T020NKEX
LCCD20T030-K
LCCD20T030N-K
LCCD20T030KEX
LCCD20T030NKEX
LCCD20T010-KC6
LCCD20T010N-KC6
LCCD20T010K6EX
LCCD20T010NK6EX
LCCD20T020-KC6
LCCD20T020N-KC6
LCCD20T020K6EX
LCCD20T020NK6EX
LCCD20T030-KC6
LCCD20T030N-KC6
LCCD20T030K6EX
LCCD20T030NK6EX
Model
LCCD20T010-K LCCD20T020-K LCCD20T030-K LCCD20T010-K LCCD20T020-K LCCD20T030-K
Rated capacity
(R.C.)
98.07 kN (10 t) 196.1 kN (20 t) 294.2 kN (30 t) 98.07 kN (10 t)
196.1 kN (20 t)
294.2 kN (30 t)
OIML R60
accuracy class
C
Maximum number
of load cell intervals
4000
6000
Humidity symbol
CH
Minimum dead
load (E
min
)
0 kg
Maximum
capacity (E
max
)
10 t
20 t
30 t
10 t
20 t
30 t
Safe load limit
(E
lim
)
15 t
30 t
45 t
15 t
30 t
45 t
Minimum
verification
interval (V
min
)
1 kg
2 kg
3 kg
1 kg
2 kg
3 kg
Rated output (R.O.) 10000±5
20000±10
30000±15
10000±5
20000±10
30000±15
Combined error
0.025%R.O.
0.016%R.O.
Compensated
temperature range
-10
°C
~+40
°C
Recommended
excitation voltage
8VDC
Maximum
excitation voltage
12VDC
Temperature effect
on zero balance
0.019%R.O. / 10
°C
Typ.
Temperature
effect on span
0.010%Load / 10
°C
Typ.
Output signal
RS-485 2wire type
Cable
diameter/length
4-
core shielded cable φ8 / 12
m
Protection class
Compliant with IP68 (Depth of water 1.5 m/100 hours)
Surge
countermeasures
Built-in gas tube arrester etc.
Net weight
Approx. 11 kg (with mounting brackets), approx. 6 kg (loadcell)
The correspondence between the color of the load cell cable core wire and the connection is as follows.
CAUTION
Be careful not to make wiring mistakes.
Red…Power
+
Green…Data
+
White…Power
-
Blue…Data
-
Yellow…Shield
・
The polarity of data is assumed to be "+" for positive logic and "-" for negative logic.