860MM
[33-55/64"]
840MM
[33-5/64"]
It is recommended to avoid installation
of dryer near high reflective objects
(mirror, stainless steel washbasins,
etc.) in order to avoid faulty function of
the presence sensor.
Recommeded
L Min. = 500 MM[19-11/16" ]
66
MM
[2
-
19
/
32
"
]
2
5
9
M
M
[1
0
-
1
3
/
6
4
"
]
If hand dryer is to be installed with hardwired
stub provided in advance of install by others.
See MT for complete reference to mounting
heights and power KO locations.
Please check if hand dryer is supplied with convenient plug in feature.
220-240V/ 12A
110-120V/ 20A
BEFORE INSTALLATION
Installation must be carried out in accordance with the current edition of the local wiring regulations
code having jurisdiction. Installation should be performed only by a qualified electrician.
INSTALLATION
1. Make sure power supply breaker is switched off. Installation must adhere to the regulations of
the current edition of the local wiring code having jurisdiction. Installation should be performed
only by a qualified electrician.
2. Place Template against wall at desired height (see mounting height recommendations on MT) and
mark locations of eight (8) mounting holes and wire service entry at hard wire entrance.
Note
: For two(2) or more dryers units, units should be no closer than 610MM[24"] on centers.
3. Drill the marked hole at
Φ
8MM / depth 38MM.
4
.
Insert Wall Anchors, Expansion [ D ] inside hole.
5. Fix Installation Bracket [ G ] on wall.
6.
If the hand dryer is supplied in hard wire type: