13)
TOKEN SUCCESS SENSOR ERROR
▶SOLUTION
※ 1 HOW TO TEST
TEST MODE → INPUT TEST
Check the sensor operation status - detected: " _ " / When not detected: " 0 "
2 Check if sunlight penetrates into the sensor area ( CHECK 1 )
3 SENSOR PCB wiring connection and connector connection status check ( CHECK 2 )
4 Check the sensor assembly status, check the presence of foreign substances inside ( CHECK 1 )
5 voltage check ( SENSOR PCB )
: PIN 1: 4.5V or more, PIN 4: GND ,
PIN 2: less than 0.5V when detected / more than 4.5V when not detected
6 SENSOR PCB replacement
7 voltage check ( MAIN PCB / CN5 )
: PIN 1: above 4.5V, PIN 8: GND
8 MAIN PCB replacement
PART NAME
CODE
PART NAME
CODE
CHUTE SENSOR PCB ASS'Y
ASAW0PCB001 MAIN PCB ASS'Y
AAV10PCB001
ERROR OR LOCATION
CHECK 1
CHECK 2
- 29 -