background image

INTERNAL WALL

24"

16" MINIMUM

FOR STEAM HOSE 

FAN

PACK

STEAM 

HUMIDIFIER

DRAIN

GROW

LIGHT

GROW

LIGHT

2 FEET

MINIMUM TO

SIDE WALL

1-1/2 FEET

MINIMUM TO CEILING

ALLOW A

3 TO 5 FOOT

PATH FOR THE

STEAM TO DISSIPATE

DEPENDING ON

TEMPERATURE

AS35FP Steam Humidifier

Quick Start Guide

Choose a location in a 

conditioned space

Install drain line

•  Secure 7/8" drain line with the hose clamp provided. 

Do not over tighten.

•  Make sure drain line has a constant downward slope and is not kinked  

or blocked.

•  If floor drain is not available, use condensate pump to route water to a drain. 

NOTE:

 The humidifier uses cold water to temper drain water to less than 140°F.

1

3

90-2196

Fan pack location

The fan pack has a set fan speed, the fan blows 
over the steam outlet to help the steam absorb 
into the surrounding air. See the figure above for 
placement guidance. Install the fan pack such that 
steam is dispersed above canopy height.

2