NO

18"

MINIMUM

NO

6

90-1666

Determine location 

for humidifier control

Do not mount humidifier control:

•  In the flow of supply registers.
•  Behind doors or in corners
•  In direct light, near lighting fixtures, or other  

appliances that give off heat.

•  Outside or in unconditioned area.

Humidifier control wiring

7

ANDEN MODEL AS35FP

STEAM HUMIDIFIER

MODEL 5558

HUMIDIFIER

CONTROL

ODT

CIRCUIT

BOARD

HUMIDISTAT

TRANSFORMER

FAN PACK

FAN PACK

24VAC

P4

YELLOW

BLUE

BLUE

YELLOW

WHITE

RED

1
2

1

2
6

12

13

14

7

8

NOTE: 

DIGITAL OUTPUT SIGNAL 

SELECTOR JUMPER (JP2) MUST BE ON 

RIGHT (DRY CONTACT) POSITION OR 

THE HUMIDIFIER WILL BE DAMAGED.

90-2349

Running and 

programming 

control

The maximum humidity set point is 90% 
and the control comes with the default 
maximum humidity set point preset to 
65%. See step 4 in 

Program Mode

 of 

ADMC manual.

Humidifier control jumper setting:

24VAC EXT.

Jumper (JP2) on right:

 24VAC dry 

contact when wiring terminals 7 and 8.

8