If your lancing device differs from the one shown here, please 
refer to the manufacturer’s manual to ensure proper usage.

To reduce the chance of infection:

● 

Never share a lancet or the lancing device.

● 

Always use a new, sterile lancet. Lancets are for single use 

only.

● 

Avoid getting hand lotion, oils, dirt, or debris when handling 

the lancets.

Stimulating blood perfusion by rubbing the puncture site prior to
blood extraction has a significant influence on the glucose value 
obtained. Blood from a site that has not been rubbed exhibits a 
measurably different glucose concentration than blood from the 
finger. When the puncture site was rubbed prior to blood 
extraction, the difference was significantly reduced.

On the lancets and the lancing device.

Please follow the suggestions below before obtaining a drop 
of blood:

  

Rub the puncture site for about 20 seconds before penetration.

  Select the puncture site either at the fingertips or another 

    body

    part  (please see section “Alternative Site Testing”

    (AST) on how to select the appropriate sites).

  Clean the puncture site using cotton moistened with 70% 

    alcohol and let it air dry.

Summary of Contents for ADF-B27

Page 1: ...Blood Glucose Meter ADF B27 ADF B27A User Manual ADF B27Adefault unit mmol L...

Page 2: ...rning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation bet...

Page 3: ...ety notice should always be taken 3 Use the device only for the intended use described in this manual 4 Do not use adjunct which are not supplied by the producer 5 Do not make the device come into con...

Page 4: ...the testing of newborns The System is to be used by a single person and should not be shared The System is intended for self testing outside the body in vitro diagnostic use by people with diabetes a...

Page 5: ...ore readily because they are full of nerve endings receptors At other body sites since nerve endings are not so condensed you will not feel as much pain as at the fingertip Food medication illness str...

Page 6: ...to use please contact local customer services or place of purchase for assistance 2 4 6 8 10 1 3 5 9 7 11 MEMORY SYMBOL Appears when you review the memory MEASUREMENT UNIT Appears with the test resul...

Page 7: ...once The test strip consists of the following parts Absorbent Hole Apply a drop of blood here The blood will be drawn in automatically Confirmation window This is where you confirm if enough blood ha...

Page 8: ...onth flashing press M until the cor rect month appears Press S 1 3 Setting the day With the day flashing Press M until the correct day appears Press S 1 5 Setting the hour With the hour flashing Press...

Page 9: ...ter the screen will dis play a flashing blood drop 2 Press S to select General or CTL mode TESTING WITH BLOOD SAMPLE o reduce the chances of infection Choose a clean dry work surface Always use a new...

Page 10: ...cose value obtained Blood from a site that has not been rubbed exhibits a measurably different glucose concentration than blood from the finger When the puncture site was rubbed prior to blood extract...

Page 11: ...test port and the meter is turned on The time and date appears on the screen NOTE Be sure to use Andesfit test strips other test strips may not produce accurate results Step 4 When the blood drop symb...

Page 12: ...etes Association Standards of Medical Care in Diabetes 2012 Diabetes Care 2012 35 Suppl 1 S11 S63 Please work with your doctor to determine a target range that works best for you The meter provides yo...

Page 13: ...eter to move the absorbent hole of test strip so it touches the drop Once the confirmation window fills completely the meter will begin counting down To avoid contaminating the control solution do not...

Page 14: ...131 Humidity 80 RH Always wash your hands with soap and water and rinse and dry completely before handling the Blood Glucose Monitoring system and Test strip Use CaviWipes see below to clean the Blood...

Page 15: ...nds thoroughly with soap and water after handling the meter lancing device or test strips 1 Model ADF B27 ADF B27A 2 Machine size 90mm L 54mm W 13mm H 3 Weight 73g excluding batteries 4 Measuring meth...

Page 16: ...your health care provider MESSAGE WHAT IT MEANS Blood glucose level is lower than 20mg dL 1 1mmol L Blood glucose level is higher than 600mg dL 33 3mmol L Meter is ready to test control solution under...

Page 17: ...into the Meter 4 Test Strip has not been fully inserted into the Meter 4 Reinsert the Test Strip into the Meter Test results are incon sistent or Control Solution test results are not within the speci...

Page 18: ...nearby electronic equipment The meter has been tested for immunity to Level 3 electrostatic discharge as specified in IEC 61326 This meter complies with immunity to radio frequency interference over...

Reviews: