background image

12

*Black&white: refer to pic as follow

Normal

Black&white

Settings

In any mode, press and hold M button until it shows video/photo/playback menu, press M again, get

into Setting menu.

For example. In video mode, press and hold M button, it would show video menu as left below:
And then, press M again to get into settings menu,as right below:

(pic 9 video menu)

(pic 10 setting menu)

Gridline Settings

(remote needed)

Use “Up” and “Down”to choose among “Cross Line” “Line” “Direction” “Location”
“Color”and “Wide”. Use “Left”and “Right”(marked as a brig&- in pic 8) to change
settings.

The microscope can’t do this mission stand along, The remote is needed.

Cross line as its name says, it’s a pair of vertical and horizontal lines located in the very middle in the

Summary of Contents for 246S

Page 1: ...Digital Microscope 246S 249S Users Manual metal stand...

Page 2: ...e 3 Video demonstration 3 Button Connection 4 Bracket installation 5 Bracket instructions 5 Quick Start 6 How to choose lens 7 Digital zoom 10 Save files to micro SD card 10 Remote 11 Settings 12 Outp...

Page 3: ...low these steps for daily cleaning as well remember to ONLY wipe the INSULATED part of the monitor 5 The screen of the monitor is very fragile please use it with care Do not drop hard press or leave i...

Page 4: ...le HDMI cable USB cable Slide holder Slides kit Tweezers Bug box P1 Package include Video demonstration Please find the video demo from the link Please type all letters properly capitalized QR code be...

Page 5: ...ower on off Mode Menu Up Digital zoom in Down Digital zoom out OK Start recording Take pictures while the device is recording Remote signal receiver where you aim remote to Focusing tube Lens fixing s...

Page 6: ...ram Bracket instructions P3 Bracket instructions Secondary Bracket Lift Boom Arm Lower Limit Stop Monitor Fixing Screws Spot Lights Clips Boom Arm V locker lock the arm in vertical direction Boom Arm...

Page 7: ...and its totally normal Trouble shooting When the monitor image stops or freezes please pin the Reset hole pic 2 to reset the device first then power on the device again Reset hole is very tiny located...

Page 8: ...tom of the focusing tube Bend the two goose neck spot lights make the field of view enough illuminated Loose the Arm V locker locate the whole monitor part to a desire height distance from the lens to...

Page 9: ...on the coin Loose the Arm V locker locate the whole monitor part to a desire height distance from the lens to the specimen should be around 12mm to 320mm then fix the V locker In order to adjust objec...

Page 10: ...lides holder Loose the Arm V locker locate the whole monitor part to a desire height distance from the lens to the specimen should be around 4mm to 5mm then fix the V locker Since the focus range is v...

Page 11: ...tton to select choose Format and confirm 5 Do not insert a card while microscope is working If you do the microscope would switch off automatically And you will have to turn it on again In order to ta...

Page 12: ...eeze Stop the image on the display works in video mode photo mode and while recording Illumination exposure compensation from 2 0 to 2 0 Sharpness up down three levels of sharpness Soft Normal Strong...

Page 13: ...ow And then press M again to get into settings menu as right below pic 9 video menu pic 10 setting menu Gridline Settings remote needed Use Up and Down to choose among Cross Line Line Direction Locati...

Page 14: ...see the following pic Pic 13 Delete line 1 before after Date Time Setting Select Date Time in setting menu press OK button to get in time setting Use up and down button to select correct number OK to...

Page 15: ...ownload the software https bit ly 3xCRDPL Currently software Microscope Measure only supports Windows system System requires Windows XP SP3 Windows 7 Windows8 Windows10 Runtime Microsoft Net Framework...

Page 16: ...Measure an ellipse Long axis radius short axis radius circumference area 3 points circle radius circumference area Measure a radius circle radius circumference area Edge detection Measure a diameter c...

Page 17: ...p of this window the result of measuring can be much more precisely Main operating window This windows shows the full view from the microscope And it is also the place where users do measuring and ima...

Page 18: ...istance for the rest steps 2 In the Calibration management set the name and unit length of the new calibration refer the picture on the right Then click Calibration meanwhile the in the toolbar should...

Page 19: ...roper place around the target 3 Special Effect Includes Edge detection Inverse color Flip horizontal Relief Sharpen and Smooth Steps 1 Choose the special effect you need in the toolbar 2 Move your cur...

Page 20: ...software can not recognize the microscope Firstly please make sure that you have connected the microscope to the PC properly and have chosen USB camera on the microscope monitor Secondly if there is...

Page 21: ...hows card error or card is full after inserting memory card to the device Please format the card after insert it into the device Format steps refer to chapter Save files to micro SD card PS If there a...

Reviews: