4.3.3. Modem
The modem is used to establish a remote connection to the Node G. The connection
may be used to change the unit’s parameters, check and clear alarms or collect
measurement and quality statistics.
Furthermore, the modem is at the Node Gs request to alert the operator when there
is an alarm. The modem may be over-the-air (wireless) or public switched telephone
network (PSTN). It is possible to install the wireless modem or the PSTN modem on
site.
)
Note: Check the communication mode between the modem and the
terminal. The following parameters should be set for a GSM modem.
Bit rate / bit per second
9600 Baud
Parity bit
No parity
Number of data bit
8 Bit
Stopbit 1
Stopbit
These settings may only be changed locally. Should a different modem be used, the
operator should ensure that the settings are changed prior to leaving the site.
4.3.3.1. Initstrings
The initialization string depends on the operator’s network and the modem. It may be
necessary to adjust the initstring in the field. The initstring for Node G web interface
is factory set.
Modem Network
Initstring
GSM 900/1800
AT&FE0S7=60S0=2\Q3+CBST=7,0,1;+IPR=57600
Siemens
MC35
via Node G web
interface
&FE0S7=60S0=2\Q3+CBST=7,0,1;+IPR=57600
table 4-1 Initstrings for a GSM modem
Summary of Contents for Node G 930
Page 1: ...ID No 7164491 Page 1 User s Manual for Node G Network Elements ...
Page 12: ...User s Manual for Node G Network Elements Page 12 M0121A2A doc For your notes ...
Page 16: ...User s Manual for Node G Network Elements Page 16 M0121A2A doc For your notes ...
Page 28: ...User s Manual for Node G Network Elements Page 28 M0121A2A doc For your notes ...
Page 52: ...User s Manual for Node G Network Elements Page 52 M0121A2A doc For your notes ...
Page 56: ...User s Manual for Node G Network Elements Page 56 M0121A2A doc For your notes ...
Page 62: ...User s Manual for Node G Network Elements Page 62 M0121A2A doc For your notes ...