User’s Manual for Node G
Network Elements
Page 46
M0121A2A.doc
Pin 3
Pin 1
Pin 2
4.3.7.3. Summary
Alarm
The summary alarm is a DC potential-free contact relay.
Observe that the cross-sectional area of the wires to be connected must be in the
range from 0.14 - 1.5 mm
2
.
Pin No.:
1
2
3
figure 4-22 Summary alarm relay
The following table indicates the three-connector pin out.
Pin No.
Contact
Maximum Resistive Load
1
Open in alarm condition
Max 1 A @ 50 VDC
2
Common
Max 2 A @ 30 VDC
3
Closed in alarm condition
Max 1 A @ 230 VAC
table 4-2 Pin assignment of relay contacts
figure 4-23 Relay contacts, alarm condition