  FD 40

 

      Dehumidifier 

Operating Instructions 

& Safety Guide

 

Getting started and operation

   

   

 

   

General Safety

 

 

 

   

 

 

   

   

Electrical Safety

   

   

   

   

   

   

   

   

0800 211 611

Dehumidifiers are for internal use only.    

This equipment should only be used by a competent 

person who has read and understood these instructions.                                                                                                                                        

Check condition of equipment before use. If unit is 

showing  any signs of damage contact your supplier 

immediately.                                                                                                                         

Never operate this equipment if you are ill, feeling tired or 

under the influence of alcohol or drugs.                        

Keep all vents and grills clear of obstructions.                                                                                   

Keep children and animals away from the dehumidifer.     

Never leave them alone in a room where the units are in 

use.                                                                                                                     

Make sure equipment is switched off and unplugged after 

use.

This unit is dual voltage and can be used via a standard 

domestic 13 amp 230 volt socket or 110 volt power supply.  

ENSURE THE VOLTAGE SELECTOR SWITCH IS IN THE CORRECT 

POSITION BEFORE CONNECTING TO ANY ELECTRICAL SUPPLY.                                                                                                                 

Always inspect plugs and power cables for damage before 

plugging into power supply.                                                              

DO NOT USE IF ANY DAMAGE IS FOUND.                                   

Ensure cables are installed to prevent hazards.                                           

If an extension lead is used, ensure it is of the correct standard 

and fully uncoiled before use.                                                                                                       

Cables must not be laid in wet or damp areas.                                                                   

Do not move equipment while operating.                                                                

Do not pull equipment by the power lead.                                                                   

It is recommended that the electrical supply to this equipment 

is protected by an RCD.

Fit correct  plug top to power input 

lead to suit operating voltage 

selected.                                                 

13 amp BS1363 230volt or 16 amp 

BS4343 Blue plug                                                      

16 amp BS4343 110 volt Yellow plug.                                

Connect plug to selected power 

supply outlet socket and switch on. 

Fig 1 

Position equipment on level ground, 

position centrally in the area 

allowing free air flow.                                        

Remove selector locking plate, 

select operating voltage required, 

re-fit locking plate. 

Fig 1

230 V

110 V