Wanguard 6.2 User Guide
Reports » Components
Server
Which server runs the Packet Sensor. Click to open a new tab with data specific to the server.
Administrators and operators can right-click to open the Server Configuration window.
Flow Sensors
The table is displayed while there is at least one active Flow Sensor.
Status
A green check mark indicates that the Flow Sensor is connected to Console. If you see a red “X”
instead, make sure that the WANsupervisor service is running and look for errors in the event
log (see page 69).
Sensor Name
Displays the name of the Flow Sensor. Click to open a new tab with data specific to the Flow
Sensor. Administrators and operators can right-click to open the Flow Sensor Configuration
window.
Interface
The interface name and a colored square with the configured graph color.
If the interface names are missing for more than 5 minutes after the Flow Sensor has started,
check the troubleshooting guide from page 44.
Pkts/s (In / Out)
Inbound and outbound packets/second throughput after IP or AS validation.
Inbound Bits/s
Inbound bits/second throughput after IP or AS validation and usage percent.
Outbound Bits/s
Outbound bits/second throughput after IP or AS validation and usage percent.
IPs (Int / Ext)
IP addresses that send or receive traffic. The Int(ernal)/Ext(ernal) IPs are the IPs inside/outside
the IP Zone. The Top Generator parameter from the Sensor configuration enables or disables
the monitoring of external IPs.
Flows/s
Flows per second received by the Flow Sensor.
Flows Delay
Because traffic data must be aggregated first, flow devices export flows with a configured delay.
Some devices export flows much later than the configured delay and this field contains the
maximum flows delay detected by the Flow Sensor.
Flow Sensor cannot run with flow delays of over
5 minutes.
Dropped
Unaccounted flows. A high number indicates a performance problem of the Flow Sensor or a
network connectivity issue with the flow exporter.
CPU%
Percentage of CPU resources used by the Flow Sensor process.
RAM
The amount of RAM used by the Flow Sensor process.
Start Time
The time when the Flow Sensor started.
Server
Which server runs the Flow Sensor. Click it to open a new tab with data specific to the server.
Administrators and operators can right-click to open the Server Configuration window.