9
Note: When counting and/ or detecting is not accurate, please check the machine as
detailed in the chart below:
Is the power cord
properly connected?
Is the fuse worn out?
Is the power switch
on?
Is the hopper sensor
properly connected to the
main board?
The belt may be too
loose or too tight.
Adjust as needed.
The counting sensor maybe
dirty. Clean it with a brush.
The rubber tongue may be
worn out. Change to the
other side or replace it with a
new one.
Counting
sensor
The MG may be dirty. Clean
it with a brush.
The UV sensor may be
broken or dirty. Clean it or
replace it with a new one.
Hopper sensor may be
dirty. Clean it with a brush.
Adjust the hopper screw.
See 3.4.
Adjust the MG sensor.
3.5 Troubleshooting