Several safety systems have been conceived during the ICON Units design and manufacture to safeguard the ope-
rator, in compliance with EN 12621:2010 Directive about paint.
8. SAFETY SYSTEMS
A 8 BAR CALIBRATED SAFETY VALVE IS INSTALLED TO ENSURE THE
PUMP WORKING PRESSURE DOES NOT EXCEED THE LIMITS INSIDE
THE FEEDING CIRCUIT.
WARNING!
DO NOT REMOVE THE VALVE PLASTIC
PROTECTION. ANY TAMPERING WITH COULD BE
DANGEROUS FOR THE OPERATOR AND COMPROMI
҃
SE THE EQUIPMENT GOOD WORKING.
8.1 SAFETY VALVE
WARNING
SECURELY GROUND PUMP, SPRAY GUN, WORKPIECE AND CONTAINERS CONTAI-
NING CLENING LIQUID USED DURING FLUSHING. USE ONLY CONDUCTIVE PAILS
PLACED ON GROUNDED SITE.
Insufficient grounding can cause fire and explosion due to the static electric sparking.
10. OPERATION
WARNING
IN CASE OF ANOMALIES DURING WORKING,
TURN 90° THE BALL VALVE LEVER FOR EMER-
GENCY STOP. IN THIS WAY THE AIR SUPPLY WILL
BE INTERRUPTED AND THE RESIDUAL PRESSURE
INSIDE THE PUMP WILL BE RELEASED.
STOP
8.2 SAFETY BALL VALVE
9. WORKABLE PRODUCTS
ANEST IWATA ICON PUMPS ARE CONCEIVED TO PAINT FERROUS MATERIAL IN GENERAL, WOOD AND PLASTIC.
WARNING
TO USE THE EQUIPMENT WITH SPECIAL PRODUCTS ASK FOR THE APPROVAL OF
THE MANUFACTURER.
DO NOT USE:
- ANY HALOGENATED HYDROCARBON SOLVENTS, SUCH AS TRICHLOROETHANE,
METHYLENE CHLORIDE OR SOMETHING LIKE THAT;
- ANY TOXIC PRODUCTS SUCH AS PETROL, KEROSENE OR COMBUSTIBLE GASES;
- ANY HERBICIDE OR PESTICIDE;- ANY RADIOACTIVE FLUID;