-10-
Do the following items periodically to use compressor in the best condition.
Inspection items
Maintenance time
Contents
daily
every
100hours
or every 6
months
Check operation
○
Refer to 3.How to operate(page 9)
Check automatic
ON/OFF function
○
Refer to 3.How to operate(page 9)
Drain filter ball
○
Refer to 3.How to operate(page 9)
Abnormal sound or vibration
○
Refer to 5.Problems and remedies
(page 13)
Intake filter
○
Clean filter by blowing air.
■ Precautions about disassembly
Be sure to turn off main electric source by pulling out electric source cord from
electric outlet before doing maintenance and inspection.
※If not, sudden operation can cause injury.
Completely exhaust compressed air inside compressor before doing maintenance
And inspection.
※If not, flying parts can cause injury during disassembly.
■ Ordering parts
Refer to parts list (page 7) and specify correct part name.